Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Bonding Technology |
ODS2 |
Silanol Activity |
High |
Particle Shape |
Spherical |
Particle Size |
3 µm |
Endfitting Type |
Parker-style |
Pore Size |
80 Å |
Format |
Column |
Surface Area |
220 |
System |
HPLC |
USP Classification |
L1 |
Inner Diameter |
4.6 mm |
Length |
250 mm |
Carbon Load |
12 % |
UNSPSC |
41115709 |
Brand |
Spherisorb |
Product Type |
Columns |
Units per Package |
1 pk |
Spherisorb ODS2 Column, 80Å, 3 µm, 4.6 mm X 250 mm, 1/pk
With the Waters Spherisorb ODS2 Column, you can easily achieve great flexibility in improving procedures and lowering solvent use. The Spherisorb ODS2 Columns are silica-based chromatographic lab equipment that are general-purpose, long-lasting, and high-efficiency. The packing material of the Waters Spherisorb ODS2 Column features intermediate ligand density with a specified carbon load of 11.5%. When you shop for lab equipment on our website, you can be confident that you are purchasing genuine Waters equipment at the greatest price. Additionally, if you decide to buy from us, you can contact a member of our staff with any questions or issues you may have, either before or after the transaction. The Spherisorb column is available in different configurations to meet any chromatographic needs.
Because the Waters Spherisorb ODS2 Columns are intended to identify and address the effects of all process parameters such as slurry solvent choice, packing pressure time, temperature, flow rate, and slurry volume, the lab equipment provides optimum performance every time. This ensures you will have the best column stability and efficiency, as well as the best peak symmetry.
Using the Waters Spherisorb ODS2 Column, you can consistently fulfill the quality standards necessary for liquid chromatography. The Waters Spherisorb ODS2 Columns are manufactured under the strictest cGMP, ISO 9002 conditions in a dedicated Waters chromatography chemistry manufacturing plant. They offer the most critical performance features: column efficiency, peak symmetry, column lifetime, and column-to-column reproducibility.
Add the Reversed-Phase QC Reference Material to your collection of lab equipment as it enables you to conduct evaluation and benchmarking of your chromatography system before analysis of critical material. It is a significantly complex reference material mixture in that it contains compounds that could be challenging to separate. The Reversed-Phase QC Reference Material contains 7 compounds, including uracil, butyl paraben, naphthalene, propranolol, dipropylphthalate, acenaphthene, and amitriptyline at pH 7.
Is There A pH Limitation For The Spherisorb ODS2 Column?
The Spherisorb ODS2 Column listed here offers a minimum pH of 2 and a maximum pH of 8.
What Is The Maximum Pressure That The Spherisorb ODS2 Column Works With?
The Spherisorb ODS2 Column featured here can comfortably work with up to 6000 psi (415 Bar) pressure. This is for conditions where the pH and temperature limits of the column are also observed.