Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Bonding Technology |
ODS2 |
Silanol Activity |
High |
Particle Shape |
Spherical |
Particle Size |
5 µm |
Endfitting Type |
Parker-style |
Pore Size |
80 Å |
Format |
Column |
Surface Area |
220 |
System |
HPLC |
USP Classification |
L1 |
Inner Diameter |
2 mm |
Length |
100 mm |
Carbon Load |
12 % |
UNSPSC |
41115709 |
Brand |
Spherisorb |
Product Type |
Columns |
Units per Package |
1 pk |
Spherisorb ODS2 Column, 80Å, 5 µm, 2 mm X 100 mm, 1/pk
The Spherisorb ODS2 Column is a general-purpose, reversed-phase, silica-based C18 column with a predetermined carbon load of 12%. It can withstand a maximum pressure of 6000 psi (415 bar) and a particle size of 5 m; however, it is always recommended to keep the pressure below the maximum allowable limit, as exposure to pressure, pH, or even temperatures extremes will result in shorter column lifetimes and negatively impact performance. Use the Spherisorb ODS2 Column to meet the quality criteria required for liquid chromatography.
Spherisorb ODS2 columns are silica-based reversed-phase C18 columns. The ODS2 packing has an intermediate ligand density with a carbon burden of 11.5 percent. Spherisorb ODS2 Columns are multi-purpose, silica-based, long-lasting, and highly efficient chromatographic columns. The column packaging processes used in its production ensure that the lab equipment always provides maximum performance and consistent results with each use. The Spherisorb ODS2 Columns address all effects and process parameters such as packaging pressure time, temperature, flow rate, slurry volume, or even slurry solvent choice. This ensures that you always have the optimum column stability, efficiency, and symmetry.
Spherisorb ODS2 Columns are manufactured in dedicated and strictly controlled Waters chromatography chemistry factories to ensure cGMP and ISO 9002 compliance. As a result, you can rely on the Spherisorb ODS2 Columns to achieve key performance features such as peak symmetry, column durability, column efficiency, and column-to-column consistency.
You can increase your productivity with the correct lab equipment. Browse through our website or refer to our catalog to learn more about the Spherisorb Columns and other products that work with them. You can shop for lab equipment straight from our website to ensure that all of your lab requirements are met, and use the website to connect with a member of our global support team as well.
You may also be interested in Spherisorb ODS2 Guard Cartridge, 80Å, 5 µm, 4.6 mm X 10 mm, 3/pk, which is designed to operate with Spherisorb ODS2 Columns to extend their lifetime and performance.
What Temperature Is Best For Spherisorb ODS2 Columns?
The Spherisorb ODS2 Column can be operated at temperatures as high as 45 degrees Celsius, but it is recommended that it be operated between 20 and 45 degrees Celsius to improve selectivity, reduce solvent viscosity, and increase mass transfer rates. Temperatures above ambient or close to/beyond the maximum limit can have a considerable and negative impact on column longevity, which can also be influenced by other parameters such as pH and buffer conditions.