Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Bonding Technology |
ODS2 |
Silanol Activity |
High |
Particle Shape |
Spherical |
Particle Size |
5 µm |
Endfitting Type |
Parker-style |
Pore Size |
80 Å |
Format |
Column |
Surface Area |
220 |
System |
HPLC |
USP Classification |
L1 |
Inner Diameter |
4.6 mm |
Length |
250 mm |
Carbon Load |
12 % |
UNSPSC |
41115709 |
Brand |
Spherisorb |
Product Type |
Columns |
Units per Package |
1 pk |
Spherisorb ODS2 Column, 80Å, 5 µm, 4.6 mm X 250 mm, 1/pk
Achieve exceptional flexibility in optimizing methods and reducing solvent consumption with the Waters Spherisorb ODS2 Column. The Spherisorb ODS2 Columns are designed to be silica-based, general-purpose, durable, and high-efficiency chromatographic columns.
Consistently meet the quality standards required for liquid chromatography with the Waters Spherisorb ODS2 Column. Manufactured in the dedicated Waters chromatography chemistry manufacturing plant under the strictest cGMP, ISO 9002 conditions, the Waters Spherisorb ODS2 Columns offer the most critical performance features: column efficiency, peak symmetry, column lifetime, and column-to-column reproducibility.
The column packing processes used ensures that the lab equipment delivers maximum performance every time as the Waters Spherisorb ODS2 Columns are designed to understand and address the effects of all process parameters such as slurry solvent choice, packing pressure time, temperature, flow rate, and slurry volume. This means that you get the best column stability and highest efficiency along with the best peak symmetry.
With the high-quality bonded phase of the Waters Spherisorb ODS2 Column, you get many different and unique separation selectivities. You can select a column configuration based on your sensitivity needs, sample capacity, mobile phase, and budgetary needs. You may be interested in other Waters Spherisorb ODS2 lab equipment, such as the Spherisorb ODS2 Guard Cartridge, 80Å, 5 µm, 4.6 mm X 30 mm, 3/pk which is designed specifically to protect, guard, and extend the column lifetime by filtering out chemical and particle contaminants.
Shop for lab equipment to select a column configuration more suited to your needs, and browse for more options from our complete product portfolio.
What pH Range And Temperatures Are Recommended For Spherisorb ODS2 Columns?
The Spherisorb ODS2 Columns operate best in pH range 2 to 8. Column lifetimes will vary and also depend on the operating temperature, and the type and concentration of buffer used. For instance, you can expect a shortened column lifetime with the use of phosphate buffer at pH 8 in combination with raised temperature. The recommended operating temperatures for Spherisorb ODS2 Columns are between 20 to 45 °C. This ensures enhanced selectivity, lower solvent viscosity, and increased mass transfer rates. It is noteworthy that any temperature above ambient may reduce the lifetime of the column. To ensure a long column lifetime, adhere to recommended pH range, temperature, and buffer conditions.