Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Bonding Technology |
ODS2 |
Silanol Activity |
High |
Particle Shape |
Spherical |
Particle Size |
5 µm |
Endfitting Type |
Parker-style |
Pore Size |
80 Å |
Format |
Column |
Surface Area |
220 |
System |
HPLC |
USP Classification |
L1 |
Inner Diameter |
4.6 mm |
Length |
100 mm |
Carbon Load |
12 % |
UNSPSC |
41115709 |
Brand |
Spherisorb |
Product Type |
Columns |
Units per Package |
1 pk |
Spherisorb ODS2 Column, 80Å, 5 µm, 4.6 mm X 100 mm, 1/pk
To satisfy the required specifications necessary for liquid chromatography, use the Spherisorb ODS2 Column. The analytical column is made under the most stringent cGMP, ISO 9002 conditions in a dedicated Waters chromatography chemistry production plant. Silica-based and polymeric chromatography materials are manufactured and packed into columns and solid-phase extraction devices at the manufacturing site. This assures that you receive top-of-the-line lab equipment that produces consistent and trustworthy analysis findings. When you buy the Spherisorb ODS2 Column, you get the most important performance features: column efficiency, peak symmetry, column longevity, and column-to-column reproducibility.
The Spherisorb ODS2 Column is a reversed-phase C18 column made of silica that contains packing with intermediate ligand density and a carbon load of 11.5 %. You can get great flexibility in optimizing procedures and lowering solvent use by using the Spherisorb ODS2 Column. The lab equipment is a silica-based, general-purpose, durable, and high-efficiency chromatographic column that may be used for a variety of purposes. The Waters Spherisorb ODS2 Column's high-quality bonded phase offers a wide range of separation selectivities. Based on your sensitivity requirements, sample capacity, mobile phase, and budgetary constraints, you can choose a column arrangement. Select the most suitable column for your needs by choosing from our wide range of lab equipment available on our website. All our products are held to the strictest quality control standards to ensure that you receive the quality that is the hallmark of Waters products.
All process parameters, such as slurry solvent choice, packing pressure time, temperature, flow rate, and slurry volume, have been studied and addressed using the Waters Spherisorb ODS2 Column. As a result, the column packing procedures utilized in its production ensure that the lab equipment always performs at its best. This implies you will have the best column stability and efficiency, as well as the best peak symmetry.
Ensure that your analytical Spherisorb ODS2 Column lasts a long time by using the Spherisorb ODS2 Guard Cartridge, 80Å, 5 µm, 4.6 mm X 30 mm, 3/pk in conjunction with the column. This is made to keep your analytical column safe from injury, increasing its life. Chemical and particulate materials are removed from the mobile phase to achieve this.
Is There A pH Limitation For The Spherisorb ODS2 Column?
The Spherisorb ODS2 Column listed here offers a minimum of 2 pH and a maximum of 8 pH.