Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Bonding Technology |
ODS2 |
Silanol Activity |
High |
Particle Shape |
Spherical |
Particle Size |
5 µm |
Endfitting Type |
Parker-style |
Pore Size |
80 Å |
Format |
Column |
Surface Area |
220 |
System |
HPLC |
USP Classification |
L1 |
Inner Diameter |
4.6 mm |
Length |
50 mm |
Carbon Load |
12 % |
UNSPSC |
41115709 |
Brand |
Spherisorb |
Product Type |
Columns |
Units per Package |
1 pk |
Spherisorb ODS2 Column, 80Å, 5 µm, 4.6 mm X 50 mm, 1/pk
The Spherisorb ODS2 Column is a general-purpose, silica-based, reversed-phase C18 column that contains packing with intermediate ligand density with a specified carbon load of 11.5%. Using the Spherisorb ODS2 Column, you can achieve exceptional flexibility in optimizing methods and reducing solvent consumption. The lab equipment has been designed to be a silica-based, general-purpose, durable, and high-efficiency chromatographic column, to cater to a wide range of applications.
Use the Spherisorb ODS2 Column to consistently meet the quality standards required for liquid chromatography. The analytical column is manufactured in the dedicated Waters chromatography chemistry manufacturing plant under the strictest cGMP, ISO 9002 conditions. At the manufacturing plant, silica-based and polymeric chromatography materials are synthesized and packed into columns and solid-phase extraction devices. This ensures that you get the highest quality lab equipment that delivers consistent and reliable analysis results. You get the most critical performance features when you purchase the Spherisorb ODS2 Column: column efficiency, peak symmetry, column lifetime, and column-to-column reproducibility.
The Waters Spherisorb ODS2 Column has been designed to understand and address the effects of all process parameters such as slurry solvent choice, packing pressure time, temperature, flow rate, and slurry volume. This is why the column packing processes used in its manufacture ensure that the lab equipment delivers maximum performance every time. This means that you get the best column stability and highest efficiency along with the best peak symmetry.
The high-quality bonded phase of the Waters Spherisorb ODS2 Column offers many different and unique separation selectivities. You can select a column configuration based on your sensitivity needs, sample capacity, mobile phase, and budgetary needs. You can find out the entire range of options through our website which also allows you to shop for lab equipment. You may, for instance, want to explore the Spherisorb ODS2 Guard Cartridge, 80Å, 5 µm, 4.6 mm X 30 mm, 3/pk, which is designed to protect your analytical column from harm, thus extending its lifetime. This is achieved by removing chemical and particulate materials from the mobile phase.
What Is The Recommended pH Range For The Spherisorb ODS2 Column?
It is recommended that an operating pH range of 2-8 be used with the Spherisorb ODS2 Column. It is also important to note that the column’s lifetime will depend on the operating temperature and buffers used.