Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
No |
Bonding Technology |
ODS1 |
Silanol Activity |
High |
Particle Shape |
Spherical |
Particle Size |
10 µm |
Endfitting Type |
Parker-style |
Pore Size |
80 Å |
Format |
Column |
Surface Area |
220 |
System |
HPLC |
USP Classification |
L1 |
Inner Diameter |
4.6 mm |
Length |
200 mm |
Carbon Load |
6 % |
UNSPSC |
41115709 |
Brand |
Spherisorb |
Product Type |
Columns |
Units per Package |
1 pk |
Spherisorb ODS1 Column, 80Å, 10 µm, 4.6 mm X 200 mm, 1/pk
Add the Spherisorb ODS1 Column to your lab equipment collection to meet all the liquid chromatography challenges of your lab. The analytical column is reliable as it is a general-purpose, silica-based, reversed-phase C18 column and designed to handle a wide range of applications.
The packing of the Spherisorb ODS1 Column uses a low ligand density with a specified carbon load of 6%, as researchers and scientists at Waters realize the criticality of the way a chromatographic column is packed. The packing helps address four very important performance features, including peak symmetry, column efficiency, column lifetime, and column-to-column reproducibility. Additionally, you can be certain of the column’s performance as the column packing processes used by Waters are developed to ensure maximum performance at all times.
Our goal is always to develop and deliver a column that is best suited to and can perform on all aspects of liquid chromatography, and it is important to understand the effect of all process parameters such as slurry solvent choice, packing pressure, time, temperature, flow rate, and slurry volume. This is why extensive research and analysis is conducted by the Waters R&D engineers to develop a packing process for each product we offer. The resulting products are available for you to purchase from us, with the guarantee that they can be relied upon to get the best peak symmetry, highest column efficiency, and best column stability.
To make sure that you have proof of the column’s quality, each Spherisorb ODS1 Column is individually tested, and a copy of the test chromatogram is supplied with each column.
Be sure to explore through our website and catalog, which contain more information on all our brands and help you to directly shop for lab equipment from us. We recommend that you also invest in the Spherisorb ODS1 Guard Cartridge, 80Å, 5 µm, 4.6 mm X 30 mm, 3/pk, to protect your analytical column’s performance.
Why Are Buffers Used In HPLC?
It is necessary to control the pH of the mobile phase by the addition of a buffer as the retention of ionizable compounds is very sensitive to the mobile phase pH. A buffer maintains the pH when a small amount of acid or base is added. Many different substances can be used for buffering in HPLC.