Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
No |
Bonding Technology |
ODS1 |
Silanol Activity |
High |
Particle Shape |
Spherical |
Particle Size |
5 µm |
Endfitting Type |
Parker-style |
Pore Size |
80 Å |
Format |
Column |
Surface Area |
220 |
System |
HPLC |
USP Classification |
L1 |
Inner Diameter |
4.6 mm |
Length |
100 mm |
Carbon Load |
6 % |
UNSPSC |
41115709 |
Brand |
Spherisorb |
Product Type |
Columns |
Units per Package |
1 pk |
Spherisorb ODS1 Column, 80Å, 5 µm, 4.6 mm X 100 mm, 1/pk
Add the general-purpose, silica-based, reversed-phase C18 Spherisorb ODS1 Column to your lab so you can benefit from its packing, which features low ligand density with a specified carbon load of 6.2%.
The Spherisorb ODS1 Column is an excellent piece of lab equipment for your liquid chromatography needs. This is because the packing of the Spherisorb ODS1 Column features low ligand density with a specified carbon load of 6%. The way a column is packed will influence four very important performance features, including peak symmetry, column efficiency, column lifetime, and column-to-column reproducibility. The column packing processes used by Waters are developed to ensure maximum performance at all times.
The R&D engineers at Waters do extensive research to develop a packing process for each product we offer as it is crucial to understand the effect of all process parameters such as slurry solvent choice, packing pressure, time, temperature, flow rate, and slurry volume in order to pack the best column. The lab equipment produced as a result of this extensive study is one you can trust and rely upon to get the best peak symmetry, highest column efficiency, and best column stability.
Each Spherisorb ODS1 Column is individually tested, and a copy of the test chromatogram is supplied with each column to make sure that you get only the most reliable lab equipment. A copy of the test chromatogram is supplied with each column so that you have the recorded guarantee that you have added dependable lab equipment in your analysis collection.
If you are interested in learning more about the complete range of Spherisorb products, the technologies used in their development, go through our website and order our catalog. You will find detailed information regarding the company and our commitment to research and will also be able to shop for lab equipment.
We recommend the purchase of the Spherisorb ODS1 Guard Cartridge, 80Å, 5 µm, 4.6 mm X 10 mm, 3/pk along with the Spherisorb ODS1 Column.
Why Are Air Bubbles Bad In Column Chromatography?
The appearance of air bubbles in practical HPLC and ion chromatography is one of the key factors for disruption of analysis. They can cause multiple issues such as shifting retention times, pulsating baselines, unexpected changes in peak areas, irregular peak shapes, pump outages, and excessively high back pressures.