Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
12 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
2.5 µm |
Endfitting Type |
Parker-style |
Pore Size |
130 Å |
Format |
Premier Column |
Surface Area |
185 |
System |
UPLC, UHPLC |
Particle Technology |
BEH |
Technique |
LC |
USP Classification |
L1 |
Inner Diameter |
2.1 mm |
Length |
50 mm |
Carbon Load |
18 % |
eCord |
Yes |
UNSPSC |
41115709 |
Application |
Oligonucleotide, Gene Therapeutics |
Brand |
XBridge |
Product Type |
Columns |
Units per Package |
1 pk |
XBridge Premier Oligonucleotide BEH C18 Column, 130Å, 2.5 µm, 2.1 x 50 mm
Oligonucleotide separation technology designed for the future is here with the XBridge Premier Oligonucleotide BEH C18 Column. This UHPLC column incorporates Ethylene Bridged Hybrid (BEH) particles and MaxPeak High Performance Surface technology to provide an all-in-one solution for oligo separations. What’s more, you can equip this column with VanGuard FIT technology to extend its lifetime across all your UHPLC assays. This way you can maximize efficiency in the lab and in turn increase business profitability.
Detritylated synthetic oligonucleotides present a series of challenges when being the chosen sample for UHPLC separations. That’s why you want a superior BEH C18 column in your toolkit for all related assays. Luckily for you, the XBridge Premier Oligonucleotide BEH C18 Column is uniquely suited to work under ion-pair, reversed-phase chromatography conditions, resulting in reliable performance time and again.
The XBridge Premier Oligonucleotide BEH C18 Column isn’t just suited for oligo separations either, as it offers premium performance for a broad range of compounds. Plus, all XBridge Premier columns provide the highest pH stability in a UHPLC column. Add these facets together and it’s easy to see why liquid chromatography labs across the globe trust Waters products to help pave the path to MS adoption.
UHPLC column protection is just as important as performance. That’s why you can couple your XBridge Premier Oligonucleotide BEH C18 Column with a VanGuard FIT Cartridge to enjoy a longer column lifetime and less risk of losses in signal intensity. What’s more, VanGuard FIT Technology can prevent your UHPLC column from suffering chemical fouling.
To further protect oligonucleotide separations from losses in signal intensity, the XBridge Premier Column line incorporates MaxPeak High Performance Surface technology. MaxPeak increases reproducibility and peak shape while reducing surface-analyte interactions that might negatively affect your data. That kind of confidence is important to have when performing oligo separations.
Protect your oligonucleotide-related UHPLC separations even further and stock your lab with all the necessary equipment when you shop with Waters. Shop for lab equipment now to check off your lab’s shopping list, or speak to your lab manager today about using Waters Corporation products.
What is a BEH C18 Column?
A BEH C18 column is a column used for general purpose, reversed-phase chromatography and offers extreme pH stability.