Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
2 pH |
pH Range Max |
11 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Bonding Technology |
Shield RP18 |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
1.7 µm |
Endfitting Type |
Parker-style |
Pore Size |
130 Å |
Format |
Premier Column |
Surface Area |
185 |
System |
UPLC |
Particle Technology |
BEH |
Technique |
LC |
USP Classification |
L1 |
Inner Diameter |
2.1 mm |
Length |
150 mm |
Carbon Load |
17 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
ACQUITY UPLC |
Product Type |
Columns |
Units per Package |
1 pk |
ACQUITY Premier BEH Shield RP18 Column with VanGuard FIT, 1.7 µm, 2.1 x 150 mm, 1/pk
Challenging reverse-phase separations are tackled each and every day by scientists across the world, and the ACQUITY Premier BEH Shield RP18 Column is tool scientists want when conquering those separations. This is in part thanks to the Ethylene-Bridged Hybrid particle technology running through this UPLC column, as it helps to promote increased retention of difficult samples, especially when using lower backpressures. What’s more, this silica column comes equipped with VanGuard FIT Technology that protects your analytical column from losses in signal intensity due to chemical or particulate fouling. This all adds up to an essential chromatography consumable you’ll want at your disposal. Get the ACQUITY Premier BEH Shield RP18 Column today and you’ll be ready for the science of tomorrow.
The embedded carbamate group in the bonded phase ligand of the ACQUITY Premier BEH Shield RP18 Column helps it to provide alternate selectivity to traditional C18 phases while providing specific retentivity for phenolic compounds. Plus, with MaxPeak High Performance Surface hardware technology included in this reverse-phase column, you can spend more time in lab and less worrying about unwanted analyte-surface interactions. This all adds up to a UPLC column that prioritizes peak shape and strong signal intensity across multiple assays.
What is VanGuard FIT Technology?
Scientists everywhere have mentioned that one of the factors in unreliable data is due to chemical or particulate fouling of the analytical column. That’s where VanGuard FIT comes in to save the day. A guard column is attached to your analytical column that prevents from that column fouling, so you can get back to the separations that are most important. This especially comes in handy when dealing with reverse-phase chromatography.
Reverse-phase chromatographic separations depend on your LC system to be operating at peak capacity. That’s why we recommend you test your system for performance on a regular basis. To help you check for performance, we’ve developed Reversed-Phase QC Reference Material. Get your own today to make sure your chromatography system is operating correctly before performing critical analysis.
To be successful in any lab, you’ll need much, much more than just breakthrough analytical columns. And at Waters, we have everything you need for that success. From quality control reference materials and analyte vials to lab informatics and software, you’ll want to come to us before performing critical analysis. Shop for lab equipment now to see everything we have to offer.
What’s the pH Range of the ACQUITY Premier BEH Shield RP18 Column?
The ACQUITY Premier BEH Shield RP18 Column offers a pH range of 2 to 11 pH.