Chemistry |
RP/Anion-exchange |
Separation Mode |
Mixed mode |
Particle Substrate |
Hybrid |
pH Range Max |
10 pH |
Temperature Limits |
60 C |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Bonding Technology |
C18 AX |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
2.5 µm |
Endfitting Type |
Parker-style |
Pore Size |
95 Å |
Format |
VanGuard FIT Cartridge |
Surface Area |
270 |
System |
UHPLC, UPLC |
Particle Technology |
BEH |
Technique |
LC |
USP Classification |
L78 |
Inner Diameter |
2.1 mm |
Length |
5 mm |
Carbon Load |
17 % |
UNSPSC |
41115709 |
Brand |
Atlantis |
Product Type |
Cartridge Columns |
Units per Package |
3 pk |
Atlantis Premier BEH C18 AX VanGuard FIT Cartridge, 2.5 µm, 2.1 x 5 mm, 3/pk
Protective laboratory equipment like the Atlantis Premier BEH C18 AX VanGuard FIT Column is compatible with the Atlantis Premier BEH C18 AX VanGuard FIT columns. It functions by preventing suspended particles and chemical contaminants from entering the analytical column, extending the column's life and reliability. In reversed-phase circumstances, the Atlantis Premier BEH C18 AX Columns offer exceptional retention for polar acidic analytes.
Matrix and sample contaminants are kept out of the analytical column by the mixed-mode, reversed-phase/anion-exchange guard cartridges. It functions by preventing suspended particles and chemical contaminants from entering the analytical column, extending the column's life and reliability.
In reversed-phase circumstances, the Atlantis Premier BEH C18 AX Columns offer exceptional retention for polar acidic analytes. It is advantageous when constructing methods to use the reversed-phase/anion-exchange mixed-mode chemistry since it is stable from pH 2 to 10 and offers complimentary selectivity to typical C18 stationary phases. The guard-column format of the VanGuard FIT Column reduces dead volume while prolonging the column's lifespan.
The Atlantis Premier BEH C18 AX VanGuard FIT Cartridge is made to function with the Atlantis Premier BEH C18 column because it uses the same high-performance packing materials. The Atlantis Premier BEH C18 AX VanGuard FIT Cartridge is a solitary component that fastens to the Atlantis Column's inlet side. By removing any chemical and particle pollutants that might be present in the mobile phase stream, the pre-column safeguards your column from harmful impurities. Additionally, it enhances and strengthens the column's analytical capabilities.
The website enables you to shop for lab equipment and reach out with any queries you may have. You might also be interested in checking out Neutrals QC Reference Material; It is possible to utilize the Neutrals QC Reference Material with any chromatographic systems that have a UV detector. It is meant to serve as a benchmarking standard for systems. There are solely neutral chemicals in the mixture. The QC Reference Material will give you confidence in your results, cut down on troubleshooting and rerun time, and allow you to compare results from different laboratories when used consistently and with control charts. This reference material can be used with many different separation techniques.
What Are The Atlantis Premier BEH C18 AX VanGuard FIT Cartridge's Operating Limitations?
It is advised to operate within or below the maximum operating limits to ensure effective productivity and the longevity of the column. The Atlantis Premier BEH C18 AX VanGuard FIT Cartridge has a maximum pH range of 10, a temperature limit of 60 C, and a maximum pressure of 18,000 psi (or 1240 Bar).