Chemistry |
RP/Anion-exchange |
Separation Mode |
Mixed mode |
Particle Substrate |
Hybrid |
pH Range Max |
10 pH |
Temperature Limits |
60 C |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Bonding Technology |
C18 AX |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
2.5 µm |
Endfitting Type |
Parker-style |
Pore Size |
95 Å |
Format |
Premier Column |
Surface Area |
270 |
System |
UHPLC, UPLC |
Particle Technology |
BEH |
Technique |
LC |
USP Classification |
L78 |
Inner Diameter |
2.1 mm |
Length |
150 mm |
Carbon Load |
17 % |
UNSPSC |
41115709 |
Brand |
Atlantis |
Product Type |
Columns |
Units per Package |
1 pk |
Atlantis Premier BEH C18 AX Column, 2.5 µm, 2.1 x 150 mm, 1/pk
The Atlantis PREMIER BEH C18 AX Column features MaxPeakTM High-Performance Surfaces. By decreasing analyte/surface interactions, which can lead to sample loss, this cutting-edge approach attempts to improve analyte recovery, sensitivity, and repeatability. It implies that the Atlantis PREMIER BEH C18 AX Column is an excellent piece of laboratory equipment that not only gives consistent, reliable analytical results but is also incredibly efficient, allowing you to prepare and use as many samples as you need.
In reversed-phase conditions, the Atlantis PREMIER BEH C18 AX column delivers outstanding retention for polar acidic analytes. The analytical column's reversed-phase/anion-exchange mixed-mode chemistry provides a stable operating pH range of 2-10. Furthermore, it offers complimentary selectivity to typical C18 stationary phases, which is highly desirable in technique development.
The Atlantis Premier BEH C18 AX Column is made with ultra-pure reagents in cGMP, ISO 9001-certified facilities. Each batch is chromatographically tested to assure product quality, and the results are constrained to small specification ranges to ensure excellent, consistent, and repeatable results.
Every Atlantis Premier BEH C18 AX Column is thoroughly tested to guarantee that only high-quality Waters products are delivered, and a Performance Chromatogram and Certificate of Batch Analysis are included in the column box or on the eCordTM Intelligent Chip. The Certificate of Analysis for each batch of packing material includes the batch number, unbonded particle analysis, bonded particle analysis, and chromatographic results and conditions. The Performance Test Chromatogram for each column includes the batch number, column serial number, USP tangent efficiency, USP tailing factor, retention factor, and chromatographic conditions. According to Waters, these data should be stored for future reference.
Shop for lab equipment and choose from a wide range of Waters products and offerings the equipment that best matches you and your laboratory needs. We recommend reviewing Atlantis Premier BEH C18 AX VanGuard FIT Column, 5 µm, 4.6 x 250 mm, 1/pk; The Atlantis Premier BEH C18 AX Columns provide excellent retention for polar acidic analytes under reversed-phase conditions. The reversed-phase/anion-exchange mixed-mode chemistry is stable from pH 2-10 and has complementary selectivity to traditional C18 stationary phases, which is desirable when doing method development. The VanGuard FIT Column format is an all-in-one, guard-column design engineered to reduce dead volume and increase column lifetime.
What Is High-Performance Liquid Chromatography (HPLC) And How Is It Used?
HPLC, or high-performance liquid chromatography, is a method for separating, identifying, and quantifying components in a mixture. This test is used for a variety of purposes and is the most commonly performed process in laboratories around the world.