Chemistry |
RP/Anion-exchange |
Separation Mode |
Mixed mode |
Particle Substrate |
Hybrid |
pH Range Max |
10 pH |
Temperature Limits |
60 C |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Bonding Technology |
C18 AX |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
1.7 µm |
Endfitting Type |
Parker-style |
Pore Size |
95 Å |
Format |
Premier Column |
Surface Area |
270 |
System |
UPLC, UHPLC |
Particle Technology |
BEH |
Technique |
LC |
USP Classification |
L78 |
Inner Diameter |
2.1 mm |
Length |
150 mm |
Carbon Load |
17 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
Atlantis |
Product Type |
Columns |
Units per Package |
1 pk |
Atlantis Premier BEH C18 AX VanGuard FIT Column, 1.7 µm, 2.1 x 150 mm, 1/pk
Under reversed-phase circumstances, the Atlantis Premier BEH C18 AX Columns provide exceptional retention for polar acidic analytes. The mixed-mode chemistry of reversed-phase/anion-exchange is stable from pH 2 to 10 and possesses complementary selectivity to typical C18 stationary phases, which is advantageous when developing techniques. The VanGuard FIT Column format is a guard-column design that reduces dead volume while increasing column longevity.
Because it is manufactured with the same high-performance packing materials as the Atlantis Premier BEH C18 column, the Atlantis Premier BEH C18 AX VanGuard FIT Column is designed to work with it. The Atlantis Premier BEH C18 AX VanGuard FIT Column is a vital piece of laboratory equipment that was designed and constructed specifically for situations requiring greater capacity for biological fluid cleanup and/or temperature control.
Use the Atlantis Premier BEH C18 AX VanGuard FIT Column to prevent unwanted entrance of sample matrix or particles onto the column without compromising separation. The laboratory equipment was designed with the purpose of prolonging the analytical columns' working lifetimes. It works in conjunction with the analytical column and can be quickly replaced to restore separation performance and extend the analytical column's life.
The Atlantis Premier BEH C18 AX VanGuard FIT Column is a single piece that attaches to the inlet side of an Atlantis Column. The pre-column protects your column from dangerous impurities by filtering out any chemical and particle pollutants that may be present in the mobile phase stream. It also boosts and improves the analytical performance of the column.
Waters' complete product line can be seen on our website or in our brochure. The website enables you to shop for lab equipment, as well as to reach out with any queries you may have.
We also recommend you to review the Atlantis Premier BEH C18 AX VanGuard FIT Cartridge, 5 µm, 3.9 x 5 mm, 3/pk; Atlantis Premier BEH C18 AX cartridges work with the Atlantis Premier BEH C18 AX VanGuard FIT columns. The mixed-mode reversed-phase/anion-exchange guard cartridges protect the analytical column from matrix and sample contaminants.
What Are The Atlantis Premier BEH C18 AX VanGuard FIT Column's Operating Limits?
The Atlantis Premier BEH C18 AX VanGuard FIT Column has a maximum pH range of 10pH, a temperature limit of 60 C, and a maximum pressure of 18,000 psi (or 1240 Bar); however, it is recommended to operate within or below the maximum operating limits to ensure efficient productivity and column longevity.