Nova-Pak C8 columns are general purpose, silica-based, reversed-phase C8 columns that are based on 4 µm particle technology. Compared to a 5 µm column, Nova-Pak columns offer higher resolution, more efficient separations, and faster chromatography.
Chemistry |
C8 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Silanol Activity |
Medium |
Particle Shape |
Spherical |
Particle Size |
4 µm |
Endfitting Type |
Waters |
Pore Size |
60 Å |
Format |
Column |
Surface Area |
120 |
System |
HPLC |
USP Classification |
L7 |
Inner Diameter |
4.6 mm |
Length |
250 mm |
Carbon Load |
4 % |
UNSPSC |
41115709 |
Brand |
Nova-Pak |
Product Type |
Columns |
Units per Package |
1 pk |
Nova-Pak C8 Column, 60Å, 4 µm, 4.6 mm X 250 mm, 1/pk
Use the Nova-Pak C8 Column, so you can decrease solvent use while preserving the resolution required for complex combinations, boosting lab productivity. The Nova-Pak C8 Column not only offers lower wait times but is also appropriate for almost every system design, sample type, and instrument platform. The Nova-Pak C8 Column is a general-purpose, reversed-phase C8 column built on the 4 m particle technology. The Nova-Pak C8 Column enables you to achieve higher resolution, more effective separations, and quicker chromatography as compared to a 5 µm column. This particular lab equipment features a particle size of 4 µm and a pore size of 60Å, providing excellent resolution and sensitivity for your chromatographic needs.
The mobile phase can traverse over a wider surface area on the Nova-Pak Column, lengthening the time it spends interacting with the elutes and bonded phase. As a result, the sample can elute more gradually, enabling more separation.
This column is packed with a C8 stationary phase, which is composed of hydrocarbon chains bonded to the silica support. The C8 phase offers moderate hydrophobicity, making it ideal for the separation of a wide range of compounds, including nonpolar and moderately polar analytes.
The 4 µm particle size of the Nova-Pak C8 Column ensures efficient and rapid separations, reducing analysis time and improving productivity. The 60Å pore size allows for optimal sample penetration and interaction with the stationary phase, leading to enhanced separation and resolution of target compounds.
The Nova-Pak C8 Column is highly reliable and provides consistent performance from batch to batch. The lab equipment is compatible with a variety of solvents and can withstand high-pressure conditions, allowing for versatility in method development and optimization.
Safely store your analytes and samples in the LCMS Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk. To ensure the safety of your solvents, solutions, and samples while preserving their chemical inertness, use the LCMS Certified Clear Glass 12 x 32 mm Screw Neck Vial. This will ensure that your analysis results are as accurate as possible. The only vials available for LC and LC/MS Analysis are those offered by Waters. The vial's screw top creates a good seal while also mechanically holding the septum in place during piercing. For repeated injections and sample preservation, the preslit PTFE/Silicone septa exhibit excellent resealing properties. From -40 °C to 200 °C, it has a working temperature range.
What Is The Recommended Flow Rate For The Nova-Pak C8 Column?
The recommended flow rate for the Nova-Pak C8 Column is between 0.5-1.0 mL/min. However, the flow rate can be adjusted depending on the specific analytical requirements and the instrumentation being used.
What Is The Maximum Pressure Limit For The Nova-Pak C8 Column?
The maximum pressure limit for the Nova-Pak C8 Column is 4000 psi (276 bar). It is important not to exceed this limit in order to prevent damage to the column and ensure accurate results.