Suggested Uses: Top-down Proteomics, Trap and Elute, Intact mass analysis
Chemistry |
C4 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
10 pH |
Maximum Pressure |
15000 psi (1034 Bar) |
Endcapped |
No |
Silanol Activity |
Medium |
Particle Shape |
Spherical |
Particle Size |
1.7 µm |
Endfitting Type |
Parker-style |
Pore Size |
300 Å |
QC Tested |
Protein |
Format |
Column |
Surface Area |
90 |
System |
Nano/Micro |
Particle Technology |
BEH |
USP Classification |
L26 |
Inner Diameter |
300 µm |
Length |
100 mm |
Carbon Load |
8 % |
UNSPSC |
41115709 |
Application |
Protein |
Brand |
nanoEase M/Z |
Product Type |
Columns |
Units per Package |
1 pk |
nanoEase M/Z Protein BEH C4 Column, 300Å, 1.7 µm, 300 µm X 100 mm, 1/pk
Use the nanoEase M/Z Protein BEH C4 Column for the best results in liquid chromatographic separation at the nano- to microscale. The lab equipment offers the best sensitivity, resolution, and repeatability for biomarker discovery and protein identification and characterization.
The nanoEase M/Z Protein BEH C4 Column version presented below uses Waters' proprietary 300A pore, C4, 1.7 m particles. Making sure appropriate connections are made to prevent peak tailing and wasteful operation helps to achieve optimal performance.
To guarantee that you only receive the best lab supplies, each batch of the nanoEase M/Z Protein BEH C4 Column is QC tested utilizing a gradient separation of a tryptic digest of cytochrome c.
The nanoEase M/Z Protein BEH C4 Column packing materials were developed specifically for use with the ACQUITY UPLC System and are created in a cGMP, ISO 9001-certified facility using ultra-pure reagents. To achieve exceptional, repeatable performance, each batch of nanoEase M/Z Protein BEH C4 Column packing material is chromatographically tested with acidic, basic, and neutral analytes. The results are constrained to narrow specification ranges. An eCordTM Intelligent Chip is used to give a Performance Chromatogram and a Certificate of Batch Analysis after each column is independently analyzed.
The nanoEase M/Z Protein BEH C4 Column's pre-assembled ZenFit Connectors are made to fit into connection ports with a V-detail appearance. The 10-32 threaded V-detail connection port is fingertight, reusable, and designed for 1/16" O.D. tubing. It can withstand pressures at 90°C. Establishing crucial nano- and microflow UPLC fluid connections is made easier as a result. With the nanoEase M/Z Protein BEH C4 Column, flow-path-induced variability in chromatographic results may be effectively eliminated.
The Waters nanoEase columns are available in a wide variety of configurations to meet your different chromatographic needs. You may also want to explore the nanoEase M/Z HSS T3 Column, 100Å, 1.8 µm, 75 µm X 200 mm, 1/pk.
What Is The pH Range Offered By The nanoEase M/Z Protein BEH C4 Column?
The Waters nanoEase M/Z Protein BEH C4 Column listed here is able to function well within the 1-10 pH range.
What Is The Maximum Pressure That The nanoEase M/Z Protein BEH C4 Column Can Sustain?
The nanoEase M/Z Protein BEH C4 Column is able to tolerate a maximum pressure of up to 15,000 psi (1034 Bar).