Suggested Uses: Bottom-up Proteomics, Nano-flow, Trap and Elute
Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
12 pH |
Maximum Pressure |
15000 psi (1034 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
1.7 µm |
Endfitting Type |
Parker-style |
Pore Size |
130 Å |
QC Tested |
Peptide |
Format |
Column |
Surface Area |
185 |
System |
Nano/Micro |
Particle Technology |
BEH |
USP Classification |
L1 |
Inner Diameter |
300 µm |
Length |
100 mm |
Carbon Load |
12 % |
UNSPSC |
41115709 |
Application |
Peptide |
Brand |
nanoEase M/Z |
Product Type |
Columns |
Units per Package |
1 pk |
nanoEase M/Z Peptide BEH C18 Column, 130Å, 1.7 µm, 300 µm X 100 mm, 1/pk
Use the nanoEase M/Z Peptide BEH C18 Column for the best results in liquid chromatographic separation at the nano- to microscale. The lab equipment offers the best sensitivity, resolution, and repeatability for biomarker discovery and protein identification and characterization.
The nanoEase M/Z Peptide BEH C18 Column version presented below uses Waters' proprietary 130A pore, C18, 1.7 µm particles. Making sure appropriate connections are made to prevent peak tailing and wasteful operation helps to achieve optimal performance. In addition to this, to guarantee that you only receive the best lab equipment, each batch of the nanoEase M/Z Peptide BEH C18 Column is QC tested utilizing a gradient separation of a tryptic digest of cytochrome c.
The nanoEase M/Z Peptide BEH C18 packing materials were developed specifically for use with the ACQUITY UPLC System and are created in a cGMP, ISO 9001-certified facility using ultra-pure reagents. To achieve exceptional, repeatable performance, each batch of nanoEase M/Z Peptide BEH C18 packing material is chromatographically tested with acidic, basic, and neutral analytes. The results are constrained to narrow specification ranges. An eCordTM Intelligent Chip is used to give a Performance Chromatogram and a Certificate of Batch Analysis after each column is independently analyzed.
The nanoEase M/Z Peptide BEH C18 Column's pre-assembled ZenFit Connectors are made to fit into connection ports with a V-detail appearance. The 10-32 threaded V-detail connection port is fingertight, reusable, and designed for 1/16" O.D. tubing. It can withstand pressures at 90°C. Establishing crucial nano- and microflow UPLC fluid connections is made easier as a result. With the nanoEase M/Z Peptide BEH C18 Column, flow-path-induced variability in chromatographic results may be effectively eliminated.
You may also want to explore the nanoEase M/Z HSS T3 Column, 100Å, 1.8 µm, 75 µm X 200 mm, 1/pk.
Are There Any Limitations To The Operating pH Offered By The nanoEase M/Z Peptide BEH C18 Column?
The nanoEase M/Z Peptide BEH C18 Column listed here is able to function well across the 1-12 pH.
What Is The Maximum Pressure That The nanoEase M/Z Peptide BEH C18 Column Can Tolerate?
This particular nanoEase M/Z Peptide BEH C18 Column is able to tolerate a maximum of 15,000 psi (1034 Bar) pressure.