Suggested Uses: Bottom-up Proteomics, Nano-flow, Trap and Elute
Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Temperature Limits |
45 C |
Maximum Pressure |
15000 psi (1034 Bar) |
Endcapped |
Yes |
Bonding Technology |
T3 |
Silanol Activity |
Medium |
Particle Shape |
Spherical |
Particle Size |
1.8 µm |
Endfitting Type |
10-32 for 1/16" male /360um open |
Pore Size |
100 Å |
Format |
Column |
Surface Area |
230 |
System |
Nano/Micro |
Particle Technology |
HSS |
USP Classification |
L1 |
Inner Diameter |
150 µm |
Length |
100 mm |
Carbon Load |
11 % |
UNSPSC |
41115711 |
Brand |
nanoEase M/Z |
Product Type |
Columns |
Units per Package |
1 pk |
nanoEase M/Z HSS T3 Column, 100Å, 1.8 µm, 150 µm X 100 mm, 1/pk
The nanoEase™ M/Z columns are optimized for nano- to micro-scale liquid chromatographic separation, providing the highest sensitivity, resolution, and reproducibility for biomarker discovery, protein identification, and characterization. Waters Columns are intended for low-dispersion nano-UPLC systems used in nano-to-microscale LC-MS analyses. Our stringent quality control measures ensure that the columns reach their full sensitivity, resolution, and reproducibility for biomarker discovery, as well as for identifying and characterizing peptides and proteins.
All nanoLC columns are designed for use up to 15 k-psi (1,000 bar) operating pressure and handle pressure fluctuations during injection extremely well and thus provide superior longevity. The columns are equipped with the ZenFit connector, an easy-to-use, fingertight, tool-free liquid connection. This ensures reproducible, leak-free connections. The fittings will fit into Waters V-Detail ports as well as into Rheodyne/Vici compatible valves.
All our lab equipment is manufactured under the strictest conditions and undergoes high standards of quality assurance so that you only receive top-quality products from your lab. Our website has products to fulfill all of your analytical demands, such as columns, guards, vials, and elution plates. We offer a variety of brands and versions that are specifically developed to fulfill the needs of every sort of chromatographic analysis. To discover the appropriate equipment for your lab needs, visit our website to shop for lab equipment directly.
Find various products that are compatible with the Symmetry Shield RP8 Column, including guards, vials, and elution plates from our website. You can shop for lab equipment to meet the demanding needs of your laboratory by using our website or browsing through our brochure.
You may also be interested in the Carbamate Analysis Kit; The Waters Carbamate Analysis Kit includes a Waters Carbamate column as well as Oasis HLB cartridges, vials, and Reference Standards. These products, designed for use with EPA Method 531.2, simplify your analysis while increasing your confidence in the results. Carbamate Column - designed and tested for high sensitivity and excellent resolution, this column is specified as the primary column for EPA Method 531.2; Oasis HLB Cartridges - for sample cleanup and concentration to ensure maximum sensitivity; Vials - certified to be clean and free of background contamination in order to provide optimized analysis; Carbamate Reference Standards - for both drinking water and wastewater, these reference materials increase your level of confidence in your results.
What Is the Importance of High Resolution in Chromatography?
Peak width and retention time, two fundamental aspects of the chromatographic process, determine resolution. Resolution measurements can be used to improve separations. The higher the resolution obtained, the better and more accurate the results can be analyzed.