Suggested Uses: Bottom-up Proteomics, Nano-flow, Trap and Elute
Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Temperature Limits |
45 C |
Maximum Pressure |
15000 psi (1034 Bar) |
Endcapped |
Yes |
Bonding Technology |
T3 |
Silanol Activity |
Medium |
Particle Shape |
Spherical |
Particle Size |
1.8 µm |
Endfitting Type |
10-32 for 1/16" male /360um open |
Pore Size |
100 Å |
Format |
Column |
Surface Area |
230 |
System |
Nano/Micro |
Particle Technology |
HSS |
USP Classification |
L1 |
Inner Diameter |
75 µm |
Length |
150 mm |
Carbon Load |
11 % |
UNSPSC |
41115711 |
Brand |
nanoEase M/Z |
Product Type |
Columns |
Units per Package |
1 pk |
nanoEase M/Z HSS T3 Column, 100Å, 1.8 µm, 75 µm X 150 mm, 1/pk
Use the nanoEase M/Z HSS T3 Column for the best outcomes in liquid chromatographic separation at the nano- to microscale. The identification and characterization of proteins, as well as the discovery of biomarkers are made possible by the analytical column, which offers the highest level of sensitivity, resolution, and repeatability. The 75 µm ID column is built using an incredibly low dispersion column design and gives the same ease of usage as more traditional columns. It is designed to withstand significant operational pressure variations and handle injection pressure changes well. As a result, the lab equipment provides greater column longevity.
To find out more about our technology, buy lab equipment, and browse the full range of our offerings, as well as all associated products and other listing alternatives, consult our catalog.
The lab equipment listed here contains 100Å pore, C18, 1.8 µm particles using Waters' patented BEH Technology. Since it is essential to ensure that appropriate connections are made to avoid peak tailing and inefficient operation in order to achieve optimal performance, extra attention is taken throughout the production process to provide the highest standards. Each batch is QC evaluated using a gradient separation of a tryptic digest of cytochrome C before being QC recognized as a Peptide separation column.
On the nanoEase Column, ZenFit Connectors have already been put together. ZenFit Connectors are meant to be utilized with the V-detail type connector ports. 1/16" O.D. tubing may fit through the 10-32 threaded port used for the V-detail connection. These fingertight couplings are reusable, easy to use, and strong enough to handle high pressure. This makes it straightforward to construct essential nano- and microflow UPLC fluid connections. The flow-path brought on by the variability in chromatographic results is considerably reduced by the nanoEase M/Z T3 Column. Due to all of these qualities, the nanoEase M/Z HSS T3 Column is a reliable lab equipment opted for by scientists.
We recommend that you explore the Clear Glass 12 x 32 mm Screw Neck Vial, 2 mL Volume, 100/pk.
What Is The pH Range Offered By The nanoEase M/Z HSS T3 Column?
The Waters nanoEase M/Z HSS T3 Column listed here is able to work well within the 2-8 pH range.
What Is The Recommended Maximum Temperature For The nanoEase M/Z HSS T3 Column?
The maximum temperature recommended for the nanoEase M/Z HSS T3 Column is 45 C.