Suggested Uses: Bottom-up Proteomics, Nano-flow, Trap and Elute
Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
10 pH |
Maximum Pressure |
15000 psi (1034 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
1.7 µm |
Endfitting Type |
10-32 for 1/16" male /360um open |
Pore Size |
130 Å |
QC Tested |
Peptide |
Format |
Column |
Surface Area |
185 |
System |
Nano/Micro |
Particle Technology |
CSH |
USP Classification |
L1 |
Inner Diameter |
75 µm |
Length |
250 mm |
Carbon Load |
15 % |
UNSPSC |
41115711 |
Application |
Peptide |
Brand |
nanoEase M/Z |
Product Type |
Columns |
Units per Package |
1 pk |
nanoEase M/Z Peptide CSH C18 Column, 130Å, 1.7 µm, 75 µm X 250 mm, 1/pk
For the best results in liquid chromatographic separation at the nano- to micro-scale, rely on the nanoEase M/Z Peptide CSH C18 Column. For the identification and characterization of proteins as well as the development of biomarkers, the lab equipment provides the greatest levels of sensitivity, resolution, and repeatability.
The nanoEase M/Z Peptide CSH C18 Column, constructed using an ultra-low dispersion design, gives the same ease of use as more conventional columns. The nanoEase M/Z Peptide CSH C18 Column, like other lab equipment with comparable chemistries, can withstand high operating pressure and handle pressure changes during injection exceedingly well, leading to an improved lifetime.
Waters' patented BEH Technology 130A pore, C18, 1.7 µm particles are present in the variant of the nanoEase M/Z Peptide CSH C18 Column that is listed above. This aids in maximizing performance by ensuring that the right connections are made to reduce peak tailing and inefficient operation.
Each batch of the nanoEase M/Z Peptide CSH C18 Column is QC tested using a gradient separation of a tryptic digest of cytochrome c before being QC accepted as a Peptide separation column in order to ensure that you only receive the highest quality lab equipment.
Discover every variation of the nanoEase M/Z Peptide CSH C18 Column and items that complement the column. While adding to your list of lab products, you can shop for lab equipment on our website and discover more about our brands and innovations.
You may also be interested in the LCMS Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk. The vial is produced in accordance with the strictest ISO 9001 guidelines and is guaranteed to meet the dimensional tolerances for autosamplers for height, breadth, neck opening, neck center, threads, and bottom thickness. These restrictions must be followed since utilizing out-of-dimension vials might result in needle breakage, system downtime, malfunctioning lab equipment, and lengthy delays in the transmission of analytical results. After being packaged for a few days, each batch of vials is additionally inspected to make sure it is clean and of high quality.
Does The nanoEase M/Z Peptide CSH C18 Column Have Any pH Limitations?
The Waters nanoEase M/Z Peptide CSH C18 Column listed here is able to function well across the 1-10 pH range for conducting analysis.
What Is The Maximum Pressure Recommended For The nanoEase M/Z Peptide CSH C18 Column?
For this particular nanoEase M/Z Peptide CSH C18 Column, the recommended maximum pressure is 15,000 psi (1034 Bar).