Suggested Uses: Bottom-up Proteomics, Nano-flow, Trap and Elute
Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
10 pH |
Maximum Pressure |
15000 psi (1034 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
1.7 µm |
Endfitting Type |
10-32 for 1/16" male /360um open |
Pore Size |
130 Å |
QC Tested |
Peptide |
Format |
Column |
Surface Area |
185 |
System |
Nano/Micro |
Particle Technology |
BEH |
USP Classification |
L1 |
Inner Diameter |
150 µm |
Length |
100 mm |
Carbon Load |
18 % |
UNSPSC |
41115711 |
Application |
Peptide |
Brand |
nanoEase M/Z |
Product Type |
Columns |
Units per Package |
1 pk |
nanoEase M/Z Peptide BEH C18 Column, 130Å, 1.7 µm, 150 µm X 100 mm, 1/pk
Use the nanoEase M/Z Peptide BEH C18 Column for the best results in liquid chromatographic separation at the nano- to microscale. The lab equipment offers the best sensitivity, resolution, and repeatability for biomarker discovery and protein identification and characterization.
The nanoEase M/Z Peptide BEH C18 Column version presented below uses Waters' proprietary 130A pore, C18, 1.7 m particles. Making sure appropriate connections are made to prevent peak tailing and wasteful operation helps to achieve optimal performance.
The nanoEase M/Z Peptide BEH C18 packing materials were developed specifically for use with the ACQUITY UPLC System and are created in a cGMP, ISO 9001-certified facility using ultra-pure reagents. To achieve exceptional, repeatable performance, each batch of nanoEase M/Z Peptide BEH C18 packing material is chromatographically tested with acidic, basic, and neutral analytes. The results are constrained to narrow specification ranges. An eCord Intelligent Chip is used to provide a Performance Chromatogram and a Certificate of Batch Analysis after each column has been carefully inspected.
The nanoEase M/Z Peptide BEH C18 Column's pre-assembled ZenFit Connectors are made to fit into connection ports with a V-detail appearance. The 10-32 threaded V-detail connection port is fingertight, reusable, and designed for 1/16" O.D. tubing. It can withstand pressures at 90°C. Establishing crucial nano- and microflow UPLC fluid connections is made easier as a result. With the nanoEase M/Z Peptide BEH C18 Column, flow-path-induced variability in chromatographic results may be effectively eliminated.
To guarantee that you only receive the best lab equipment, each batch of the nanoEase M/Z Peptide BEH C18 Column is QC tested utilizing a gradient separation of a tryptic digest of cytochrome c.
You may also want to explore LCGC certified, Amber Glass 12 x 32 mm Screw Neck Vial, with Cap and PTFE Septum, 2 mL Volume, 100/pk.
What Is The pH Range For The nanoEase M/Z Peptide BEH C18 Column?
The Waters nanoEase M/Z Peptide BEH C18 Column listed here is able to work well within the 1-10 pH range.
What Is The Maximum Pressure That The nanoEase M/Z Peptide BEH C18 Column Can Tolerate?
The nanoEase M/Z Peptide BEH C18 Column listed here has been designed to withstand a maximum of 15,000 psi (1034 Bar) pressure.