Suggested Uses: Bottom-up Proteomics, Nano-flow, Trap and Elute
Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
10 pH |
Maximum Pressure |
15000 psi (1034 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
1.7 µm |
Endfitting Type |
10-32 for 1/16" male /360um open |
Pore Size |
130 Å |
QC Tested |
Peptide |
Format |
Column |
Surface Area |
185 |
System |
Nano/Micro |
Particle Technology |
BEH |
USP Classification |
L1 |
Inner Diameter |
75 µm |
Length |
100 mm |
Carbon Load |
18 % |
UNSPSC |
41115711 |
Application |
Peptide |
Brand |
nanoEase M/Z |
Product Type |
Columns |
Units per Package |
1 pk |
nanoEase M/Z Peptide BEH C18 Column, 130Å, 1.7 µm, 75 µm X 100 mm, 1/pk
Use the nanoEase M/Z Peptide BEH C18 Column for the best results in liquid chromatographic separation at the nano- to microscale. The lab equipment offers the best sensitivity, resolution, and repeatability for biomarker discovery and protein identification and characterization.
The nanoEase M/Z Peptide BEH C18 Column version presented below uses Waters' proprietary 130A pore, C18, 1.7 m particles. Making sure appropriate connections are made to prevent peak tailing and wasteful operation helps to achieve optimal performance.
To guarantee that you only receive the best lab equipment, each batch of the nanoEase M/Z Peptide BEH C18 Column is QC tested utilizing a gradient separation of a tryptic digest of cytochrome c.
The nanoEase M/Z Peptide BEH C18 packing materials were developed specifically for use with the ACQUITY UPLC System and are created in a cGMP, ISO 9001-certified facility using ultra-pure reagents. To achieve exceptional, repeatable performance, each batch of nanoEase M/Z Peptide BEH C18 packing material is chromatographically tested with acidic, basic, and neutral analytes. The results are constrained to narrow specification ranges. An eCordTM Intelligent Chip is used to give a Performance Chromatogram and a Certificate of Batch Analysis after each column is independently analyzed.
In order to give the same ease of use as more conventional columns, the nanoEase M/Z Peptide BEH C18 Column incorporates an ultra-low dispersion design. The nanoEase M/Z Peptide BEH C18 Column can resist high working pressures and handle pressure fluctuations during injection extraordinarily well, making it equivalent to other lab equipment with similar chemistries. This results in an increased lifetime.
The nanoEase M/Z Peptide BEH C18 Column's pre-assembled ZenFit Connectors are made to fit into connection ports with a V-detail appearance. The 10-32 threaded V-detail connection port is fingertight, reusable, and designed for 1/16" O.D. tubing. It can withstand high pressures at 90°C. Establishing crucial nano- and microflow UPLC fluid connections are made easier as a result. With the nanoEase M/Z Peptide BEH C18 Column, flow-path-induced variability in chromatographic results may be effectively eliminated.
You may also want to explore a similar product, the nanoEase M/Z HSS T3 Column, 100Å, 1.8 µm, 75 µm X 200 mm, 1/pk.
What Is The pH Range Of The nanoEase M/Z Peptide BEH C18 Column?
The nanoEase M/Z Peptide BEH C18 Column listed here offers a broad pH range of 1-10.
What Is The Maximum Pressure That The nanoEase M/Z Peptide BEH C18 Column Can Sustain?
The nanoEase M/Z Peptide BEH C18 Column can sustain a maximum of 15,000 psi (1034 Bar) pressure.