Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Temperature Limits |
45 C |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Bonding Technology |
Shield RP18 |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
2.7 µm |
Endfitting Type |
Parker-style |
Pore Size |
90 Å |
Format |
Column |
Surface Area |
100 |
System |
UHPLC, UPLC |
Particle Technology |
Solid Core |
USP Classification |
L1 |
Inner Diameter |
3 mm |
Length |
150 mm |
Carbon Load |
6.4 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
CORTECS |
Product Type |
Columns |
Units per Package |
1 pk |
CORTECS Shield RP18 Column, 90Å, 2.7 µm, 3 mm X 150 mm, 1/pk
You can gain from the lab equipment's adaptability by including the CORTECS Shield RP18 Column in your workspace because it is made to be all-purpose and produce outcomes with great efficacy. Based on a solid-core particle that allows balanced retention of bases, acids, and neutrals at low and mid-range pH, it produces excellent peak shapes for basic analytes at low pH.
Choose the CORTECS Shield RP18 Column when you want to take advantage of complementing selectivity to C8 and C18 stationary phases. In contrast to straight-chain alkyl columns, the column uses an embedded carbamate group in the ligand of the bonded phase, which offers alternate selectivity, particularly for phenolic chemicals. The lab equipment's solid core particle shape provides great efficiency and lower back pressures as compared to totally porous particles of comparable particle size.
Use the all-purpose CORTECS Shield RP18 Column to resolve complicated combinations or to retain resolution while boosting throughput. The column produces exceptional results because its solid-core particles perform better by reducing each of the three terms in the van Deemter equation. The B term is dropped because the solid core particles have lower particle porosity, which reduces axial diffusion, while the A term is lowered because the solid core particles pack more uniformly. Their solid core enhances heat transport, lowering radial temperature gradients, which lowers the C term.
By simply increasing the flow rate of the technique, the column enables you to enhance sample throughput with equivalent or even superior peak capacities. By allowing you to run numerous samples simultaneously while maintaining separation performance, it also aids in lowering the costs associated with running your lab.
Enhance the analytical column's ability by using the CORTECS Shield RP18 VanGuard Cartridge, 90Å, 2.7 µm, 2.1 mm X 5 mm, 3/pk in conjunction with it. The cartridge attaches to the column directly and filters out any unwanted contaminants from entering the mobile phase.
What’s the Difference Between XSelect Premier C18 and CSH C18 Columns?
The XSelect Premier CSH C18 Column presents a distinctive selectivity option compared to the conventional C18 particle morphology.