Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Temperature Limits |
45 C |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Bonding Technology |
Shield RP18 |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
2.7 µm |
Endfitting Type |
Parker-style |
Pore Size |
90 Å |
Format |
Column |
Surface Area |
100 |
System |
UHPLC, UPLC |
Particle Technology |
Solid Core |
USP Classification |
L1 |
Inner Diameter |
2.1 mm |
Length |
100 mm |
Carbon Load |
6.4 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
CORTECS |
Product Type |
Columns |
Units per Package |
1 pk |
CORTECS Shield RP18 Column, 90Å, 2.7 µm, 2.1 mm X 100 mm, 1/pk
Profit from the adaptability of the CORTECS Shield RP18 Column by adding it to your lab because it is designed to be general-purpose and give high-efficiency outcomes. It is built on a solid-core particle that retains acids, bases, and neutrals in a balanced manner at low and mid-range pH, resulting in excellent peak shape for basic analytes at low pH.
Choose the CORTECS Shield RP18 Column when you need complementing selectivity to C8 and C18 stationary phases. In comparison to straight-chain alkyl columns, the lab equipment uses an embedded carbamate group in the bonded phase ligand, which gives alternate selectivity, especially for phenolic chemicals. The solid core particle shape of the CORTECS Column delivers great efficiency and lower back pressures as compared to totally porous particles of equal particle size.
The general-purpose CORTECS Shield RP18 Column will resolve complicated mixes or retain resolution while improving throughput. The lab equipment produces exceptional results because its solid-core particles improve performance by decreasing each of the three terms of the van Deemter equation. The A term decreases as the solid core particles pack more uniformly, while the B term decreases as the solid core particles have smaller particle porosity, reducing axial diffusion. Their solid core enhances heat transport and reduces radial temperature gradients, lowering the C term.
By simply increasing the flow rate of the technique, you can improve sample throughput while maintaining or improving peak capacity. It also helps to lower lab operating expenses by allowing you to run numerous samples in the same amount of time without compromising separation performance.
Browse our website to find lab equipment such as the CORTECS column listed above, as well as other goods that operate with it.
Use the CORTECS Shield RP18 VanGuard Cartridge, 90Å, 2.7 µm, 2.1 mm X 5 mm, 3/pk to extend the lifetime of your CORTECS column. The cartridge is manufactured using the same packing materials that are present in the column and is hence, ideally suited to it. It works by removing any unwanted particles or chemicals from entering the mobile stream.
What Are The Temperature Limits For The CORTECS Shield RP18 Column?
The CORTECS Shield RP18 Column listed here has a maximum temperature limit of 45 C.
What Is The Maximum Pressure That The CORTECS Shield RP18 Column Can Take?
The CORTECS Shield RP18 Column listed here can sustain up to a maximum of 18000 psi (1240 Bar) pressure.