Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Temperature Limits |
45 C |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Bonding Technology |
Shield RP18 |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
2.7 µm |
Endfitting Type |
Parker-style |
Pore Size |
90 Å |
Format |
Column |
Surface Area |
100 |
System |
UHPLC, UPLC |
Particle Technology |
Solid Core |
USP Classification |
L1 |
Inner Diameter |
2.1 mm |
Length |
50 mm |
Carbon Load |
6.4 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
CORTECS |
Product Type |
Columns |
Units per Package |
1 pk |
CORTECS Shield RP18 Column, 90Å, 2.7 µm, 2.1 mm X 50 mm, 1/pk
Use the CORTECS Shield RP18 Column in analyses when you need supplementary selectivity to the C8 and C18 stationary phases. You can take advantage of the lab equipment's embedded carbamate group in the bonded phase ligand to achieve alternative selectivity, notably for phenolic compounds as compared to straight-chain alkyl columns. The solid core particle shape of the CORTECS Column delivers great efficiency and lower back pressures as compared to totally porous particles of comparable particle size.
You may quickly resolve complicated combinations or retain resolution while improving throughput using the general-purpose CORTECS Shield RP18 Column. Because its solid-core particles perform better by decreasing each of the three terms of the van Deemter equation, the column is able to produce outstanding results. The B term is dropped because the solid core particles have lower particle porosity, which reduces axial diffusion, while the A term is lowered because the solid core particles pack more uniformly. As their solid core enhances heat transfer and lowers radial temperature gradients, they lower the C term.
The CORTECS Shield RP18 Column is made to be versatile and produce high-efficiency results, bringing about significant advantages. The solid-core particle that the lab equipment is built around allows balanced retention of acids, bases, and neutrals at low and mid-range pH. Even at low pH levels, these characteristics lead to the delivery of outstanding peak shape for basic analytes.
With comparable or even superior peak capacities, the CORTECS Shield RP18 Column makes it simple to boost your sample throughput. This can be accomplished by simply increasing the method's flow rate. The lab equipment allows you to analyze numerous samples simultaneously while maintaining analysis speed without compromising separation performance, which lowers your lab operation costs.
Protect your column using the CORTECS Shield RP18 VanGuard Cartridge, 90Å, 2.7 µm, 2.1 mm X 5 mm, 3/pk. It filters out any unwanted chemical or particulate contaminants from the mobile stream.
Is There A Maximum Pressure Recommended For The CORTECS Shield RP18 Column?
This particular CORTECS Shield RP18 Column has been designed to tolerate a maximum of 18000 psi (1240 Bar) pressure.
What Is The Recommended pH Range For Use With The CORTECS Shield RP18 Column?
The CORTECS Shield RP18 Column listed here is able to work well within the 2-8 pH range.