SKU: 186008492
CORTECS T3 Column, 120Å, 2.7 µm, 4.6 mm X 50 mm, 1/pk

CORTECS T3 Column | 186008492


Streamline Purchasing with Customized Quotes

Streamline Purchasing with Customized Quotes

Shop on Waters.com and add items to your cart

Navigate to the Shopping Cart

Select Request a Quote to get your quote instantly


Product Description

CORTECS T3 columns are compatible with 100% aqueous mobile phases, and provide excellent retention for polar and non-polar analytes. The particle morphology offers high efficnecy and lower backpressure when compared to fully porouse particles of similar particle size. CORTECS T3 provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

Specifications

  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Silica

  • pH Range Min

    2 pH

  • pH Range Max

    8 pH

  • Temperature Limits

    45 C

  • Maximum Pressure

    18000 psi (1240 Bar)

  • Endcapped

    Yes

  • Bonding Technology

    T3

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    2.7 µm

  • Endfitting Type

    Parker-style

  • Pore Size

    120 Å

  • Format

    Column

  • Surface Area

    100

  • System

    UHPLC, UPLC

  • Particle Technology

    Solid Core

  • USP Classification

    L1

  • Inner Diameter

    4.6 mm

  • Length

    50 mm

  • Carbon Load

    4.7 %

  • UNSPSC

    41115709

  • Brand

    CORTECS

  • Product Type

    Columns

  • Units per Package

    1 pk

Product Support

Documents

Documents



What do you want to do?

What do you want to do?

Related Products

Back To Top Back To Top

CORTECS T3 Column, 120Å, 2.7 µm, 4.6 mm X 50 mm, 1/pk

To increase productivity and efficiency, use the CORTECS Solid Core T3 Column. To increase sample throughput, all that is necessary is to increase the method's flow rate. The CORTECS Solid Core T3 Column is compatible with 100% aqueous mobile phases and provides improved retention for both polar and nonpolar analytes.

When compared to fully porous particles of comparable particle size, the CORTECS Solid Core T3 Column reduces back pressure and improves resolution when evaluating complex samples. The CORTECS T3 columns are compatible with 100% aqueous mobile phases and provide strong retention for both polar and nonpolar analytes. The particle form offers superior efficiency and lower back pressure as compared to fully porous particles of comparable particle size. CORTECS T3 has a long lifespan, excellent peak form, and very little column MS bleed.

Utilize the CORTECS Solid Core T3 Column to expedite analysis without sacrificing effective separation. You can run more samples in the same amount of time using the CORTECS Solid Core T3 Column while using less lab equipment and waiting less time for results. In order to provide lab equipment of the highest standard that will consistently offer accurate and reproducible findings, every step of the CORTECS Solid Core T3 Column's production process is painstakingly controlled and supervised.

Browse through our website to review the extensive catalog of Waters products, and shop for lab equipment as per your needs.

You may also be interested in CORTECS T3 Method Validation Kit, 120Å, 2.7 µm, 4.6 mm X 50 mm, 3/pk; Columns from three separate batches are provided by CORTECS T3 method validation kits. The CORTECS T3 columns offer high retention for both polar and nonpolar analytes and are compatible with 100% aqueous mobile phases. When compared to completely porous particles of comparable particle size, the particle shape provides excellent efficiency and lower back pressure. Long lives, superb peak form, and extremely little column MS bleed are all features of CORTECS T3.

How Should Filtration Be Done?

Before adding a sample to the syringe, draw around 1 mL of air into the device. This will enable the air to exit the syringe with the sample. The filter device's fluid retention is reduced by this "air purge." The filtered solution should now be injected into the syringe. Twist the filled syringe onto the filter device while holding the filter device in one hand without using excessive effort. Start the filtration process by applying light pressure.