Chemistry |
C8 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
2.7 µm |
Endfitting Type |
Parker-style |
Pore Size |
90 Å |
Format |
Method Validation Kit |
Surface Area |
100 |
System |
UHPLC, UPLC |
Particle Technology |
Solid Core |
USP Classification |
L7 |
Inner Diameter |
3 mm |
Length |
50 mm |
Carbon Load |
4.5 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
CORTECS |
Product Type |
Column Kits |
Units per Package |
3 pk |
CORTECS C8 Method Validation Kit, 90Å, 2.7 µm, 3 mm X 50 mm, 3/pk
CORTECS C8 method validation kits provide columns of three different batches. CORTECS C8 columns are used for general purpose method development under low pH test conditions. The C8 ligand is preferred for some assays because it is less hydrophobic and, therefore, less retentive compared to C18 phases.
Count on the CORTECS C8 Method Validation Kit if you are looking for the best UHPLC columns for separating extremely hydrophobic substances. All linked hydrophobic chemical separations are now easier than ever due to the lower hydrophobicity of the CORTECS C8 Columns in the CORTECS C8 Method Validation Kit. Furthermore, compared to conventional C18 bonded phases, the C8 column chemistry is less hydrophobic. The lab equipment is perfect for researchers who want to transition to a new column technology or use the CORTECS C8 Columns for a range of applications.
Scientists from all over the world are interested in developing an LC column that can withstand lower back stresses. Low back pressures can be used with the CORTECS C8 Method Validation Kit while still achieving great throughput and quick technique development. This CORTECS C8 Method Validation Kit will provide you with the confidence you need in any liquid chromatography investigations when you contrast the CORTECS line to comparable lab equipment.
The need to quickly separate a variety of compounds has always worried scientists. With the CORTECS C8 Method Validation Kit, that worry is no longer a problem because the CORTECS silica columns can be used, cleaned, and reused quickly due to solid-core technology. At Waters, we also offer mass spectrometry equipment, lab software, reference materials for LC quality control, and much more. Shop for lab equipment straight from us to discover how all of our incredible product lines assist researchers in helping to make the world a better and safer place.
You may also want to purchase the CORTECS C8 VanGuard Cartridge, 90Å, 2.7 µm, 2.1 mm X 5 mm, 3/pk, which is designed to protect your column from unwanted pollutants.
Across What pH Does The CORTECS C8 Method Validation Kit Operate?
The CORTECS C8 Method Validation Kit listed here is able to operate across the 2-8 pH.
What Is The Maximum Pressure That The CORTECS C8 Method Validation Kit Can Sustain?
The CORTECS C8 Method Validation Kit listed here has been designed to tolerate a maximum of 18000 psi (1240 Bar) pressure.