Chemistry |
Phenyl |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Temperature Limits |
45 C |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Bonding Technology |
Phenyl-Hexyl |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
2.7 µm |
Endfitting Type |
Parker-style |
Pore Size |
90 Å |
Format |
Column |
Surface Area |
100 |
System |
UHPLC, UPLC |
Particle Technology |
Solid Core |
USP Classification |
L11 |
Inner Diameter |
3 mm |
Length |
150 mm |
Carbon Load |
5.9 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
CORTECS |
Product Type |
Columns |
Units per Package |
1 pk |
CORTECS Solid Core Phenyl Column, 90Å, 2.7 µm, 3 mm X 150 mm, 1/pk
To get great efficiency and reduce operating back pressure, opt for the Waters CORTECS Solid Core Phenyl Column. When compared to fully porous particles of similar particle size, the lab equipment performs better. Because of this, you can carry out approaches employing standard LC instrumentation while maintaining your effectiveness and resolution. To improve resolution for co-eluting peaks in complicated sample combinations, longer columns can be employed.
Take advantage of analyte interactions with the benzyl ring by using the CORTECS Solid Core Phenyl Column's alternate selectivity to C8 and C18 stationary phases. The changes in selectivity for this phase are more pronounced for aromatic compounds when using methanol as the organic modifier. In addition, the lab equipment will have a very low column MS bleed, a long lifetime, and a good peak form. On our online store, you may find the whole selection of CORTECS columns, which are offered in a variety of chemistries, pore and particle sizes, and dimensions. Also, you can purchase lab equipment straight from us.
The CORTECS Solid Core Phenyl Column packing materials were created expressly for use with the ACQUITY UPLC System and are produced in a cGMP, ISO 9001 accredited facility using ultra-pure reagents. Each batch of the CORTECS Solid Core Phenyl Column packing material is chromatographically tested with acidic, basic, and neutral analytes to ensure remarkable, consistent performance. The results are provided on the eCordTM Intelligent Chip in the form of a Performance Chromatogram and Certificate of Batch Analysis after each column is individually examined. The Certificate of Analysis includes both the results of the analytical tests and the bonded phase batch number.
We recommend that you also explore and invest in the Reversed-Phase QC Reference Material. Seven substances, including uracil, butyl paraben, naphthalene, propranolol, dipropylphthalate, acenaphthene, and amitriptyline at pH 7, are included in the reversed-phase quality control reference material. The benchmark performance of your analytical HPLC or UPLC equipment should be verified using this standard mixture. This QC Reference Material is a carefully formulated blend of neutral, acidic, and basic components, as well as a void marker.
The Reversed-Phase QC Reference Material is a very complex mixture of reference material because it contains components that can be challenging to separate. It is suitable for use when regularly carrying out difficult tests because it is designed to deliver this level of complexity. It functions with a variety of system lab equipment and column chemistries, sizes, and shapes.
What Temperature Limits Should Be Observed When Using The CORTECS Solid Core Phenyl Column?
The Waters CORTECS Solid Core Phenyl Column listed here is able to tolerate a maximum of 45 C temperature.