Product Description

Spherisorb SAX columns contain a silica-based quaternary ammonium bonded sorbent. The column is listed as USP L14 and is used for anion-exchange separations.

Specifications

  • Chemistry

    Anion-Exchange

  • Separation Mode

    Ion-Exchange

  • Particle Substrate

    Silica

  • pH Range Min

    2 pH

  • pH Range Max

    8 pH

  • Temperature Limits

    45 C

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    No

  • Bonding Technology

    SAX

  • Silanol Activity

    High

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Endfitting Type

    Waters

  • Pore Size

    80 Å

  • Format

    OBD Prep Column

  • Surface Area

    220

  • System

    HPLC Preparative

  • Technique

    LC/MS, LC

  • USP Classification

    L14

  • Inner Diameter

    10 mm

  • Length

    250 mm

  • Carbon Load

    4 %

  • UNSPSC

    41115709

  • Brand

    Spherisorb

  • Product Type

    Preparative Columns

  • Units per Package

    1 pk

Product Support

Documents

Documents



What do you want to do?

What do you want to do?

Related Products

Back To Top Back To Top

Spherisorb SAX OBD Prep Column, 80Å, 5 µm, 10 mm X 250 mm, 1/pk

You can consistently fulfill the quality criteria necessary for liquid chromatography with the Waters Spherisorb SAX OBD Prep Column. The Spherisorb SAX OBD Prep Column, like all other lab equipment created by Waters, is produced in the specific Waters chromatography chemistry manufacturing facility under the most stringent cGMP, ISO 9002 guidelines. The most important performance characteristics, including column efficiency, peak symmetry, column longevity, and column-to-column reproducibility, are provided by the Waters Spherisorb SAX OBD Prep Column.

You can rely on the Waters Spherisorb SAX OBD Prep Column to give you exceptional flexibility in technique optimization and solvent usage reduction. The chromatographic column made of silica is intended to be versatile, strong, and efficient.

Because the Spherisorb SAX OBD Prep Column is built on understanding and addressing the effects of all process parameters, including slurry solvent choice, packing pressure time, temperature, flow rate, and slurry volume, you can rely on it to deliver the best column stability, highest efficiency, along with best peak symmetry.

Consult our catalog to browse and shop for lab equipment, and find all connected items, and different variations of the same listing, in addition to our entire selection of products. There you may also learn how to get in touch with our many offices across the world and learn about the newest technological advancements.

You may also want to explore the Preparative Chromatography Mix Standard. A distinctive collection of standards and mixtures makes up the Quality Control Reference Material portfolio. Before analyzing crucial material, the user can benchmark and assess their chromatography system using these products. The Preparative Chromatography Standard contains Diclofenac sodium salt, Diphenhydramine hydrochloride, and Flavone in DMSO at a concentration of 5 mg/mL each. The benchmark performance of your preparation/purification system should be verified using this standard mixture. This specific QC Reference Material is a specially created blend of neutral, acidic, and basic substances, as well as a void marker. It works with different column chemistries, sizes, and system hardware.

What Is The pH Range For The Spherisorb SAX OBD Prep Column?

The Waters Spherisorb SAX OBD Prep Column listed here is able to work within the 2-8 pH range.

What Is The Maximum Recommended Operating Temperature For The Spherisorb SAX OBD Prep Column?

The Waters Spherisorb SAX OBD Prep Column listed here can operate with a maximum temperature of 45 C.