Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Temperature Limits |
45 C |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Bonding Technology |
ODS2 |
Silanol Activity |
High |
Particle Shape |
Spherical |
Particle Size |
5 µm |
Endfitting Type |
Waters |
Pore Size |
80 Å |
Format |
OBD Prep Column |
Surface Area |
220 |
System |
HPLC Preparative |
Technique |
LC, LC/MS |
USP Classification |
L1 |
Inner Diameter |
10 mm |
Length |
250 mm |
Carbon Load |
12 % |
UNSPSC |
41115709 |
Brand |
Spherisorb |
Product Type |
Preparative Columns |
Units per Package |
1 pk |
Spherisorb ODS2 OBD Prep Column, 80Å, 5 µm, 10 mm X 250 mm, 1/pk
Utilize the Spherisorb C18 OBD Prep Column to enhance procedures with exceptional flexibility and less solvent use. The laboratory apparatus consists of a general-purpose, silica-based, reversed-phase C18 column with packing with moderate ligand density and a specified carbon load of 11.5%. A reliable, highly effective piece of chromatographic machinery that can handle a range of applications is the preparation column. The lab equipment was designed with a variety of uses in mind.
The Spherisorb C18 OBD Prep Column offers a wide range of different separation selectivities due to the use of a high-quality bonded phase. You can select a column configuration based on your needs for sensitivity, sample capacity, mobile phase, and budgetary restrictions. You may learn about the complete range of options offered under the Spherisorb brand through our website, which also lets you shop for lab equipment.
The Spherisorb C18 OBD Prep Column was created by Waters experts after extensive research to identify and address the effects of all process parameters, including slurry solvent choice, packing pressure time, temperature, flow rate, and slurry volume. Because of the results of this extensive research, the column packing techniques used in its construction ensure that the lab equipment consistently operates at its best. This suggests that you also get the finest column stability and efficiency in addition to the best peak symmetry.
The stringent requirements required for liquid chromatography will be continuously met by the Spherisorb C18 OBD Prep Column. Under the strictest cGMP, ISO 9002 requirements, the silica-based and polymeric chromatography materials are manufactured and packed into columns and solid-phase extraction devices in the Waters chromatography chemistry production factory. By taking proper precautions, you can be sure that the lab equipment is of the highest quality and that the results of the studies are correct and trustworthy. When you utilize the Spherisorb C18 OBD Prep Column in your lab, it provides the most crucial performance qualities required for optimum performance, including column efficiency, peak symmetry, column longevity, and column-to-column reproducibility. You may also be interested in the AutoPurification System Standard.
What Is The pH Range Offered By The Spherisorb ODS2 OBD Prep Column?
The Waters Spherisorb ODS2 OBD Prep Column is able to offer a pH range of 2-8.
What Are The Temperature Limits Of The Spherisorb ODS2 OBD Prep Column?
The Spherisorb ODS2 OBD Prep Column listed here can tolerate a maximum of 45 C.