XBridge Protein BEH C4 OBD Columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare to traditional C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery, and improve peak capacity.
Chemistry |
C4 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
10 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
No |
Silanol Activity |
Low |
Molecular Weight Range Max |
150000 |
Particle Shape |
Spherical |
Particle Size |
5 µm |
Endfitting Type |
Waters |
Pore Size |
300 Å |
QC Tested |
Protein |
Format |
OBD Prep Column |
Surface Area |
90 |
System |
HPLC |
Particle Technology |
BEH |
USP Classification |
L26 |
Inner Diameter |
10 mm |
Length |
100 mm |
Carbon Load |
8 % |
UNSPSC |
41115709 |
Application |
Protein |
Brand |
XBridge |
Product Type |
Preparative Columns |
Units per Package |
1 pk |
To assure the stability of peptide separation techniques, the XBridge Protein BEH C4 Column underwent quality control testing using a peptide map. Modern, well-characterized bonding techniques for the C18 ligand are used to achieve this. With the variety of samples used in proteomics, protein characterization, and peptide synthesis, it also ensures predictable behavior. The resulting analytical column provides reproducible synthetic peptide and protein digest separations from batch to batch. The lab equipment is manufactured using methods that guarantee stable particle structure and bonding chemistry across a wide pH and at high temperatures.
Profit from the Protein Separation Technology of the XBridge Protein BEH C4 Column, which combines BEH technology and utilizes synthetic particles that provide the finest quality along with reliable performance.
The XBridge Protein BEH C4 Column provides excellent peptide separation for a wide range of peptides. Additionally, it provides sharp, symmetrical peaks for optimal resolution. The XBridge Protein BEH C4 Column offers excellent peak shape and retention in formic acid and trifluoroacetic acid for optimum chromatography.
Browse our catalog to find more variations of the item featured here, items that work with it, and to buy lab equipment. Additionally, it will provide you access to our offices across the world and allow you to get in touch with staff members if you have any questions about the technology or the products.
Use the XBridge Protein BEH C4 Prep Guard Cartridge, 300 Å, 5 µm, 10 mm x 10 mm, 1/pk in conjunction with the XBridge prep column in order to get more accurate and reliable results. The guard cartridge has been designed to act as a barrier that prevents any unwanted chemical or particulate contaminants from entering the mobile phase and interfering with the analysis. To ensure that there is no decline in performance standards, the cartridge is manufactured using the same packing materials as those in the column.
Across What pH Range Does The XBridge Protein BEH C4 OBD Prep Column Operate?
The Waters XBridge Protein BEH C4 OBD Prep Column listed here is able to function well across the 1-10 pH range.
What Is The Recommended Maximum Pressure For The XBridge Protein BEH C4 OBD Prep Column?
This particular XBridge Protein BEH C4 OBD Prep Column is able to sustain a maximum pressure of 6,000 psi (415 Bar).