SKU: 186008179
XBridge BEH Phenyl OBD Prep Column, 130Å, 5 µm, 10 mm X 250 mm, 1/pk,

XBridge BEH Phenyl OBD Prep Column | 186008179


Streamline Purchasing with Customized Quotes

Streamline Purchasing with Customized Quotes

Shop on Waters.com and add items to your cart

Navigate to the Shopping Cart

Select Request a Quote to get your quote instantly


Product Description

XBridge BEH Phenyl columns provide complementary selectivity to C18 stationary phases, especially for polyaromatic compounds. This most chemically stable commercially available Phenyl sorbent on the market and provides you with ultra-low column bleed, long column lifetimes and excellent peak shape.

Specifications

  • Chemistry

    Phenyl

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    1 pH

  • pH Range Max

    12 pH

  • Temperature Limits

    80 C (Low pH)/60 C (High pH)

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Bonding Technology

    Phenyl-Hexyl

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Endfitting Type

    Waters

  • Pore Size

    130 Å

  • Format

    OBD Prep Column

  • Surface Area

    185

  • System

    HPLC Preparative

  • Particle Technology

    BEH

  • Technique

    LC, LC/MS

  • USP Classification

    L11

  • Inner Diameter

    10 mm

  • Length

    250 mm

  • Carbon Load

    15 %

  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Preparative Columns

  • Units per Package

    1 pk

Hazaradous Material This product contains hazardous material which requires special freight handling. Additional charges may apply.

Product Support

Documents

Documents



What do you want to do?

What do you want to do?

Related Products

Back To Top Back To Top

XBridge BEH Phenyl OBD Prep Column, 130Å, 5 µm, 10 mm X 250 mm, 1/pk

With the addition of the XBridge BEH Phenyl OBD Prep Column, you will be able to achieve complementary selectivity to C18 stationary phases, especially for the polyaromatic compounds. You get higher flexibility in developing orthogonal methods for particularly challenging separations. Using this lab equipment, you can benefit from ultra-low column bleed, long column lifetimes, and excellent peak shape as it is the most chemically stable commercially available Phenyl sorbent on the market.

The XBridge BEH Phenyl OBD Prep Column is based on Optimum Bed Density (OBD) technology, and it will assist you in getting higher efficiency. The OBD technology enables the XBridge BEH Phenyl OBD Prep Column to have the ability to directly scale from UPLC or HPLC screening to lab-scale purification, which assists in maximizing your productivity when scaling up screening methods. The OBD design of the Prep Column makes it highly resistant to mechanical chromatographic bed failure and makes your system resistant to poor solubility and pressure shocks associated with large volumes of pure organic solvents.

The XBridge BEH Phenyl Column also offers a wide operating pH range (1-12) when it is compared to traditional phenyl liquid chromatography columns, enabling a more robust method development. Additionally, the trifunctional bonding used in the phenyl hexyl-ligand enables XBridge column to offer exceptional low and high pH stability, making it the most reproducible phenyl column in the market.

Find various products that are compatible with the XBridge BEH Phenyl OBD Prep Column, including guards, vials, elution plates, from our website. The website enables you to shop for lab equipment and reach out with any queries you may have. You can direct these queries and concerns to a member of our staff, located in one of our numerous offices located globally.

You may also want to review the Reversed-Phase QC Reference Material; the Quality Control Reference Materials portfolio is a unique collection of standards and mixtures. These products allow the user to evaluate and benchmark their chromatography system before the analysis of critical material. The products in the portfolio are all specially formulated based on the expertise of Waters scientists. The Reversed-Phase QC Reference Material is a significantly complex reference material mixture in that it contains compounds that could be challenging to separate. It is designed to provide this complexity and is appropriate when complex assays are routinely performed. It can be used with a variety of column chemistries, dimensions, and system hardware.

What Is The Maximum Pressure And pH Range The XBridge BEH Phenyl OBD Prep Column Can Operate Within?

The XBridge BEH Phenyl OBD Prep Column can easily tolerate operating pressures up to 6000 psi (or 415 Bar), along with the pH range of 1 to 12, making it extremely robust and giving useful for a wide range of applications. However, you should note that working at the extremes of pressures, pH and/or temperatures will drastically impact column efficiency and lifetime.