Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
12 pH |
Temperature Limits |
80 C (Low pH)/60 C (High pH) |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
5 µm |
Endfitting Type |
Waters |
Pore Size |
130 Å |
Format |
OBD Prep Column |
Surface Area |
185 |
System |
HPLC Preparative |
Particle Technology |
BEH |
Technique |
LC, LC/MS |
USP Classification |
L1 |
Inner Diameter |
10 mm |
Length |
250 mm |
Carbon Load |
18 % |
UNSPSC |
41115709 |
Brand |
XBridge |
Product Type |
Preparative Columns |
Units per Package |
1 pk |
XBridge BEH C18 OBD Prep Column, 130Å, 5 µm, 10 mm X 250 mm, 1/pk
Get higher recoveries while maximizing your productivity with the Waters XBridge BEH C18 OBD Prep Column. It is crucial lab equipment as it provides longer column lifetimes, which means you do not need to replace the column often, leading to reduced costs.
Achieve lab-scale separations for greater throughput in a faster, more efficient manner using the XBridge BEH C18 OBD Prep Column. You can get more efficiency through the Optimum Bed Density (OBD) preparative columns as well as have the ability to directly scale from UPLC or HPLC screening to lab-scale purification and you can maximize your productivity when scaling up screening methods.
The packing process and design of the XBridge BEH C18 OBD Prep Column is Waters-patented and makes it possible for you to get predictable, uniform density profiles throughout the column. It also removes the possibility for any voids because during the capping process, there is no overcompression or disruption in any non-uniform way.
Get exceptional resistance to mechanical chromatographic bed failure using the XBridge BEH C18 OBD Prep Column. The OBD design of the column is resistant to poor solubility and pressure shocks associated with large volumes of pure organic solvent. The Optimum Bed Density (OBD) design is specially formulated to exhibit integrity and stability required in a preparative column used in rapid, high-purity, compound isolations. In addition to this, make use of consistent column-to-column performance, reducing the costs through extended lifetimes. This is achieved by using ultra-pure reagents and adhering to the strictest manufacturing conditions such as the cGMP, ISO 9001:2000.
Shop for lab equipment, and find our complete range of XBridge columns, across a wide range of applications through our website.
You may also be interested in the Preparative Chromatography Mix Standard which is used to benchmark the system before conducting any critical analysis. It is a specially formulated mix that includes a void marker, neutral, acidic, and basic compounds. It includes 5 mg/mL each of Diclofenac sodium salt, Diphenhydramine hydrochloride, and Flavone in DMSO.
What Pressure Can The XBridge BEH C18 OBD Prep Column Sustain?
The recommended operating pressure range for the XBridge BEH C18 OBD Prep Column is up to 6000 psi (400 bar or 40 Mpa). However, in order to maximize the column and system’s lifetimes, any pressure above 4000-5000 psi should be avoided.