Chemistry |
Phenyl |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
12 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Bonding Technology |
Phenyl-Hexyl |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
2.5 µm |
Endfitting Type |
Parker-style |
Pore Size |
130 Å |
Format |
XP VanGuard Cartridge |
Surface Area |
185 |
System |
UHPLC, UPLC |
Particle Technology |
BEH |
USP Classification |
L11 |
Inner Diameter |
2.1 mm |
Length |
5 mm |
Carbon Load |
15 % |
UNSPSC |
41115709 |
Brand |
XBridge |
Product Type |
Guards |
Units per Package |
3 pk |
XBridge BEH Phenyl XP VanGuard Cartridge, 130Å, 2.5 µm, 2.1 mm X 5 mm, 3/pk
XBridge BEH Phenyl VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This particular cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. XBridge BEH Phenyl analytical columns containing 2.5 µm sorbent particles.
Connect your UPLC XBridge BEH Phenyl analytical columns to the XBridge BEH Phenyl XP VanGuard Cartridge to ensure that they survive longer without compromising their chromatographic analytical performance. The cartridge keeps the UPLC, UHPLC, and HPLC separation efficiency of the columns while eliminating chemical and particle impurities.
The XBridge BEH Phenyl XP VanGuard Cartridge was created specifically for reversed-phase liquid chromatography with Waters UPLC columns. The VanGuard Cartridge is a single item that may be immediately attached to the intake side of a Waters XBridge UPLC Column due to its design.
The XBridge BEH Phenyl XP VanGuard Cartridge is simple to set up and operate. It protects your XBridge BEH Phenyl Column from potentially harmful pollutants. The lab equipment boosts and improves the analytical performance of the column by filtering out any chemical and particle contaminants that may be present in the mobile phase stream.
The XBridge BEH Phenyl XP VanGuard Cartridge, when used in conjunction with your analytical column, is one of the first guard column devices specifically intended for routine usage and can withstand pressures up to 18,000 psi (1240 bar) in applications run on the ACQUITY UPLC System. Waters' patented BEH Technology, 130 Å pore, and 2.5µm particles are included in this package. Each batch of the XBridge BEH Phenyl XP VanGuard Cartridge is QC tested using a peptide map to ensure consistent performance and increased analytical column life. This way, you can be sure that the lab equipment will work the same way for the rest of its life.
You may also want to explore and invest in the LCGC Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk, which is designed to store your analytes and samples safely.
What pH Range Does The XBridge BEH Phenyl XP VanGuard Cartridge Operate Across?
The XBridge BEH Phenyl XP VanGuard Cartridge listed here is able to work well across the 1 - 12 pH range.