Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Temperature Limits |
45 C |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
2.7 µm |
Endfitting Type |
Parker-style |
Pore Size |
90 Å |
Format |
Column |
Surface Area |
100 |
System |
HPLC |
Particle Technology |
Solid Core |
USP Classification |
L1 |
Inner Diameter |
3 mm |
Length |
75 mm |
Carbon Load |
6.6 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
CORTECS |
Product Type |
Columns |
Units per Package |
1 pk |
CORTECS C18 Column, 90Å, 2.7 µm, 3 mm X 75 mm, 1/pk
CORTECS C18 Columns are general purpose, high-efficiency columns based on a solid-core particle that offer balanced retention of acids, bases, and neutrals at low and mid-range pH.
Use the all-purpose, charged surface CORTECS C18 Column to resolve complicated combinations or to retain resolution while boosting throughput. The solid-core particles on which the CORTECS C18 Column is built provide greater performance by decreasing each of the three terms in the van Deemter equation, which enables the column to provide such excellent results. The B term is dropped because the solid core particles have lower particle porosity, which reduces axial diffusion, while the A term is lowered because the solid core particles pack more uniformly. Their solid core enhances heat transport, lowering radial temperature gradients, which lowers the C term.
You can browse our website or skim through our catalog to see further variations of the listing here as well as our entire selection of products to see our most recent offerings and shop for lab equipment.
By simply increasing the flow rate of the technique, the column enables you to enhance sample throughput with equivalent or even superior peak capacities. It also enables the use of shorter columns than those used for the first separation while keeping comparable peak capacities and providing shorter re-equilibration times. Consequently, employing the CORTECS C18 Column will allow you to run more samples in the same amount of time without sacrificing separation performance, which will save your lab operation costs.
Protect your CORTECS C18 column from unwanted contaminants by using the CORTECS C18 VanGuard Cartridge, 90Å, 2.7 µm, 2.1 mm X 5 mm, 3/pk. The cartridge is manufactured using the exact materials as the column, making it an ideal match. It works by preventing the entrance of any chemical or particulate matter into the mobile phase, so there is no interference with the analysis, giving more accurate and reliable results.
What Is The pH Range For The CORTECS C18 Column?
This particular CORTECS C18 Column offers a pH range of 2-8 pH.
Are There Any Temperature Limits For The CORTECS C18 Column?
The CORTECS C18 Column listed here is able to function well with up to a maximum of 45 C. To ensure that the column continues to work at its optimum throughout its lifetime, it is recommended that a lower temperature than the maximum limit be used.