Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Temperature Limits |
45 C |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
2.7 µm |
Endfitting Type |
Parker-style |
Pore Size |
90 Å |
Format |
Column |
Surface Area |
100 |
System |
HPLC |
Particle Technology |
Solid Core |
USP Classification |
L1 |
Inner Diameter |
2.1 mm |
Length |
50 mm |
Carbon Load |
6.6 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
CORTECS |
Product Type |
Columns |
Units per Package |
1 pk |
CORTECS C18 Column, 90Å, 2.7 µm, 2.1 mm X 50 mm, 1/pk
Benefit from the versatility of the CORTECS C18 Column by adding lab equipment to your collection. The CORTECS C18 Column is designed to be general-purpose and deliver high-efficiency results. The CORTECS C18 Column is based on a solid-core particle that offers balanced retention of acids, bases, and neutrals at low and mid-range pH in addition to being general-purpose and delivering high-efficiency results. Due to these attributes of the analytical CORTECS column, you can easily achieve excellent peak shape for basic analytes at low pH.
The CORTECS C18 Column gives you the ability to resolve complex mixtures or maintain resolution while increasing throughput using the general-purpose, charged surface of the lab equipment. The column is able to deliver such exceptional results as the solid-core particles, on which it is based, give better performance by lowering each of the three terms of the van Deemter equation. The A term is lowered as the solid core particles pack more uniformly, while the B term is lowered as the solid core particles exhibit lower particle porosity which reduces axial diffusion. They lower the C term as their solid core improves heat transfer, reducing radial temperature gradients.
Leverage the CORTECS C18 Column in order to increase sample throughput with comparable or even better peak capacities by simply raising the flow rate of the method. In addition to this, with the use of the CORTECS C18 Column, you can use a shorter column length compared to the original separation while maintaining similar peak capacities and delivering quicker re-equilibration time. As it provides the speed of analysis without impairing separation performance, you can reduce your lab operation costs by using the CORTECS C18 Column. This can be done while having the ability to run multiple samples in the same amount of time.
The CORTECS C18 Column is available in a variety of configurations, all of which you can browse through and select as per your need using our online shop. You can also shop for lab equipment directly from us.
We also recommend that you purchase the CORTECS C18 VanGuard Cartridge, 90Å, 2.7 µm, 2.1 mm X 5 mm, 3/pk to protect your column.
What Is The pH Range For CORTECS C18 Column?
The CORTECS C18 Column listed here works well across the 2-8 pH range.