SKU: 186007312
XBridge Protein BEH C4 OBD Prep Column, 300 Å, 5 µm, 19 mm x 100 mm, 1/pk

XBridge Protein BEH C4 OBD Prep Column | 186007312


Streamline Purchasing with Customized Quotes

Streamline Purchasing with Customized Quotes

Shop on Waters.com and add items to your cart

Navigate to the Shopping Cart

Select Request a Quote to get your quote instantly


Product Description

XBridge Protein BEH C4 OBD Columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare to traditional C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery, and improve peak capacity.

Specifications

  • Chemistry

    C4

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    1 pH

  • pH Range Max

    10 pH

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    No

  • Silanol Activity

    Low

  • Molecular Weight Range Max

    150000

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Endfitting Type

    Waters

  • Pore Size

    300 Å

  • QC Tested

    Protein

  • Format

    OBD Prep Column

  • Surface Area

    90

  • System

    HPLC

  • Particle Technology

    BEH

  • USP Classification

    L26

  • Inner Diameter

    19 mm

  • Length

    100 mm

  • Carbon Load

    8 %

  • UNSPSC

    41115709

  • Application

    Protein

  • Brand

    XBridge

  • Product Type

    Preparative Columns

  • Units per Package

    1 pk

Hazaradous Material This product contains hazardous material which requires special freight handling. Additional charges may apply.

Product Support

Documents

Documents



What do you want to do?

What do you want to do?

Related Products

Back To Top Back To Top

XBridge Protein BEH C4 OBD Prep Column, 300 Å, 5 µm, 19 mm x 100 mm, 1/pk

XBridge Protein BEH C4 OBD Columns are QC tested and optimized to separate proteins based on size, hydrophobicity, and isoelectric point. If you compare it to traditional C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery, and improve peak capacity.

Excellent peptide separation for a variety of peptides is provided by the XBridge Protein BEH C4 OBD Column. The lab equipment also creates narrow, symmetrical peaks for optimal resolution. For the best chromatography, the XBridge Protein BEH C4 OBD Column offers outstanding peak shape and retention in formic acid and trifluoroacetic acid.

Shop for lab equipment and find further iterations of the item listed here as well as items that are compatible with it by browsing our catalog.

The XBridge Protein BEH C4 OBD Column is QC confirmed with a peptide map to ensure the stability of peptide separation techniques. This is made possible by employing well-studied, state-of-the-art C18 ligand bonding procedures. Additionally, it guarantees reliable outcomes when a variety of samples are used in proteomics, protein characterization, and peptide synthesis. Synthetic peptide and protein digest separations are constant from batch to batch in the analytical column that results. The manufacturing processes used to create the lab equipment enable stable particle structure and bonding chemistry over a broad pH range and at high temperatures.

We recommend that you also invest in the LCGC Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk. All Waters LC/GC certified vials are additionally UV-tested by HPLC, a test that finds minute amounts of impurities used in production and packing.

What Is The Minimum And Maximum pH Range For The XBridge Protein BEH C4 OBD Prep Column?

The XBridge Protein BEH C4 OBD Prep Column listed here offers an operating pH range of 1-10 pH.

What Is The Maximum Pressure That The XBridge Protein BEH C4 OBD Prep Column Can Sustain?

The XBridge Protein BEH C4 OBD Prep Column has been designed to be able to tolerate a maximum pressure of 6000 psi (415 Bar). However, it is recommended that the operating pressure be less than the maximum limit in order to keep the column functioning at its optimum.