Chemistry |
C4 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
10 pH |
Maximum Pressure |
10000 psi (690 Bar) |
Endcapped |
No |
Silanol Activity |
Medium |
Particle Shape |
Spherical |
Particle Size |
1.7 µm |
Pore Size |
300 Å |
QC Tested |
Protein |
Format |
Separation Device |
Surface Area |
90 |
System |
Nano/Micro |
Particle Technology |
BEH |
USP Classification |
L26 |
Inner Diameter |
150 µm |
Length |
100 mm |
Carbon Load |
8 % |
UNSPSC |
41115854 |
Application |
Protein |
Brand |
iKey |
Product Type |
Columns |
Units per Package |
1 pk |
iKey Protein BEH C4 Separation Device, 300Å, 1.7 µm, 150 µm X 100 mm, 1/pk
Use a new approach to microscale chromatography by adopting the high-pressure, microfluidic iKey Protein BEH C4 Separation Device. The iKey Separation device is one of the enabling technologies behind the ionKey/MS system. By physically integrating a UPLC separation into the mass spectrometer, the ionKey/MS System produces a significant improvement in sensitivity and enables scientists to achieve unparalleled separation and detection.
The use of the innovative iKey Protein BEH C4 Separation Device eliminates the need for traditional, manual fitting connections and greatly simplifies the microflow-LC user experience while minimizing extra-column dispersion and the potential for manual variability. The iKey lab equipment brings microflow LC into the mainstream of chromatographic laboratories. This particular listing is 100mm in length and 150 µm I.D. However, it is also available in another variant that also has a 150 µm internal diameter and is 50 mm in length. You can shop for the lab equipment directly from our online store.
Contained in the iKey Protein BEH C4 Separation Device is a ceramic substrate produced using a modified ceramic manufacturing process that contains a single analytical separation channel packed with the stationary phase, an electrospray emitter, a column heater, and an integrated memory device.
The number of injections, maximum backpressure, and the number of sample sets run are maintained by the integrated memory on the iKey Protein BEH C4 Separation Device. An integrated column heater allows the temperature of the lab equipment to be controlled. In addition to this, as the iKey Separation Device is manufactured to exacting specifications, it provides outstanding peak symmetry for maximum sensitivity and accurate quantitation. Each iKey Separation Device is individually tested to ensure that it passes stringent quality control requirements. When it is compared to conventional chromatographic systems, successful day-to-day performance of the ionKey/MS System requires certain considerations. The iKey Protein BEH C4 Separation Device, along with its variants, is the only analytical consumable device compatible with the ionKey/MS System.
You may also want to explore in detail the iKey BEH C18 Separation Device, 130Å, 1.7 µm, 150 µm X 50 mm, 1/pk.
What pH Range Can The iKey Protein BEH C4 Separation Device Operate On?
The iKey Protein BEH C4 Separation Device delivers optimum performance across a wide operational pH range, pH 1–10.