Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
11 pH |
Endcapped |
Yes |
Silanol Activity |
Low |
Molecular Weight Range Min |
1000 |
Molecular Weight Range Max |
15000 |
Particle Shape |
Spherical |
Particle Size |
1.7 µm |
Endfitting Type |
Parker-style |
Pore Size |
130 Å |
QC Tested |
Peptide |
Format |
Column |
Surface Area |
185 |
System |
UHPLC, UPLC |
Particle Technology |
CSH |
USP Classification |
L1 |
Inner Diameter |
1 mm |
Length |
150 mm |
Carbon Load |
15 % |
UNSPSC |
41115709 |
Application |
Peptide |
Brand |
ACQUITY UPLC |
Product Type |
Columns |
Units per Package |
1 pk |
ACQUITY UPLC Peptide CSH C18 Column, 130Å, 1.7 µm, 1 mm X 150 mm, 1K - 15K, 1/pk
The universal ACQUITY UPLC Peptide CSH C18 Column provides alternate selectivity that is ideal for a wide range of chemicals. Because it is manufactured on the Charged Surface Hybrid (CSH) particle platform, the analytical column has outstanding peak shape and enhanced loading capacity. This is especially true for basic chemicals in the mobile phase when the pH is low, and the ionic strength is low. Use the lab equipment’s broad selectivity range in a variety of applications. The ACQUITY UPLC Peptide CSH C18 Column not only has outstanding selectivity, but it also has a high standard of necessary performance features such as superior peak shape for basic chemicals, reduced column bleed, and efficiency.
Waters ACQUITY UPLC CSH130 C18 1.7 µm particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of the ACQUITY UPLC Peptide CSH C18 Column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications.
Using the ACQUITY UPLC Peptide CSH C18 Column, develop robust and simply transferable procedures that can be easily replicated even if your laboratories are located in different parts of the world. The laboratory equipment was created with a global audience in mind.
Avoid the drawbacks of TFA while still achieving the best outcomes achievable with TFA. This is because the ACQUITY UPLC Peptide CSH C18 Column uses CSH technology to simulate TFA (trifluoroacetic acid) peak shape without actually using TFA. A more MS-friendly mobile phase, such as formic acid, is used in the lab equipment. Because formic acid does not have the lingering chromatographic effects of an ion-pairing agent, the lab equipment allows for faster and easier technique development.
Only the strictest conditions are used to make the ACQUITY UPLC Peptide CSH C18 Column, as with all Waters lab equipment. You may rest assured that the lab equipment will not need to be replaced frequently and will produce consistent findings year after year.
You may also want to explore the Cytochrome C Digestion Standard.
What Is The Carbon Load Of The ACQUITY UPLC Peptide CSH C18 Column?
The ACQUITY UPLC Peptide CSH C18 Column listed here has a Carbon Load of 15 %.