Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
11 pH |
Endcapped |
Yes |
Silanol Activity |
Low |
Molecular Weight Range Min |
1000 |
Molecular Weight Range Max |
15000 |
Particle Shape |
Spherical |
Particle Size |
1.7 µm |
Endfitting Type |
Parker-style |
Pore Size |
130 Å |
QC Tested |
Peptide |
Format |
Column |
Surface Area |
185 |
System |
UHPLC, UPLC |
Particle Technology |
CSH |
USP Classification |
L1 |
Inner Diameter |
1 mm |
Length |
50 mm |
Carbon Load |
15 % |
UNSPSC |
41115709 |
Application |
Peptide |
Brand |
ACQUITY UPLC |
Product Type |
Columns |
Units per Package |
1 pk |
ACQUITY UPLC Peptide CSH C18 Column, 130Å, 1.7 µm, 1 mm X 50 mm, 1K - 15K, 1/pk
Create reliable and transferable procedures with the ACQUITY UPLC Peptide CSH C18 Column that can be easily replicated even if your laboratories are spread out across the globe. The lab equipment was created with the global market in mind.
Avoid TFA's drawbacks while achieving the good outcomes TFA is capable of. This is due to the fact that the ACQUITY UPLC Peptide CSH C18 Column uses CSH technology to simulate TFA (trifluoroacetic acid) peak shape performance. The column makes use of a mobile phase that is better for MS, like formic acid. Formic acid does not exhibit the lingering chromatographic effects of an ion-pairing agent; therefore, the lab equipment enables faster and simpler technique development.
Use the versatile ACQUITY UPLC Peptide CSH C18 Column to obtain alternative selectivity appropriate for a wide range of chemicals. The analytical column's use of the Charged Surface Hybrid (CSH) particle platform results in an outstanding peak shape and higher loading capacity. This is especially true for basic chemicals when mobile-phase conditions are low pH and weak ionic strength. Use the column's wide range of selectivity in its broadest possible range of applications. The ACQUITY UPLC Peptide CSH C18 Column delivers outstanding peak shape for fundamental chemicals, little column bleed, and efficiency in addition to high levels of exceptional selectivity.
Only the strictest conditions are employed to create the ACQUITY UPLC Peptide CSH C18 Column, as with other lab equipment made by Waters. You can be sure that the lab equipment will consistently produce reliable results and will not need to be replaced frequently. Learn more about the many ACQUITY UPLC Peptide CSH C18 Column variations that are offered on our website and created to meet your various analytical demands.
You may also want to explore the Cytochrome C Digestion Standard. By breaking down Bovine Heart Cytochrome C (Uniprot # P62894) with sequencing-grade trypsin, the Cytochrome C Digestion Standard was created. According to tight quality control standards that are attested to on the certificate of analysis that is supplied, each batch of the digestion standard is created. Applications for protein digestion standards range from evaluating and benchmarking HPLC and UPLC columns to assessing the performance of mass spectrometry and chromatography equipment.
What Is The USP Classification Of The ACQUITY UPLC Peptide CSH C18 Column?
The ACQUITY UPLC Peptide CSH C18 Column listed here carries a USP classification of L1.
What Is The Molecular Weight Range Offered By The ACQUITY UPLC Peptide CSH C18 Column?
The column's minimum molecular weight range is 1,000, and the maximum is 15,000.