Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
2 pH |
pH Range Max |
12 pH |
Temperature Limits |
60 C |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Bonding Technology |
Shield RP18 |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
10 µm |
Pore Size |
125 Å |
Format |
Prep Guard Cartridge |
Surface Area |
175 |
System |
HPLC Preparative |
Technique |
LC, LC/MS |
USP Classification |
L1 |
Inner Diameter |
30 mm |
Length |
10 mm |
Carbon Load |
15 % |
UNSPSC |
41115709 |
Brand |
XTerra |
Product Type |
Guards |
Units per Package |
1 pk |
XTerra Shield RP18 Prep Guard Cartridge, 125Å, 10 µm, 30 mm X 10 mm, 1/pk
To safeguard and increase the lifespan of your XTerra Shield RP18 analytical column, use the Guard Cartridge. The lab equipment enhances the performance of the analytical column by lowering particle contamination from the mobile phase stream. All 30 mm I.D. XTerra Shield RP18 analytical columns with a 10 µm sorbent particle size are compatible with this cartridge.
Operating and setting up the XTerra Shield RP18 Prep Guard Cartridge is straightforward. It defends against possibly dangerous contaminants for your XTerra Shield RP18 Column. By removing any chemical and particle impurities that might be present in the mobile phase stream, the lab equipment enhances and optimizes the analytical performance of the column.
The XTerra Shield RP18 Prep Guard Cartridge is one of the first guard column devices designed expressly for everyday use and can sustain high pressures in applications run on the ACQUITY UPLC System when used in conjunction with your analytical column. To ensure consistent performance and longer analytical column life, each batch of the XTerra Shield RP18 Prep Guard Cartridge undergoes quality control testing utilizing a peptide map. This ensures that the lab equipment will continue to function in the same manner for the duration of its lifespan.
To ensure that your UPLC XTerra Shield RP18 analytical columns last longer without sacrificing their chromatographic analytical performance, connect them to the XTerra Shield RP18 Prep Guard Cartridge. The cartridge removes chemical and particle contaminants while maintaining the UPLC, UHPLC, and HPLC separation performance of the columns.
You may want to learn more about the Preparative Chromatography Mix Standard. Before analyzing crucial material, these items enable the user to assess and benchmark their chromatography equipment. All of the goods in the portfolio were particularly created using the scientist's knowledge at Waters. Diclofenac sodium salt, Diphenhydramine hydrochloride, and Flavone are each present in the Preparative Chromatography Standard at a concentration of 5 mg/mL in DMSO. To verify the benchmark performance of your preparation/purification system, utilize this standard mixture.
Is There A pH Range That The XTerra Shield RP18 Prep Guard Cartridge Adheres To?
This particular XTerra Shield RP18 Prep Guard Cartridge works well across the 2-12 broad pH range.
What Are The Temperature Limits Of XTerra Shield RP18 Prep Guard Cartridge?
The XTerra Shield RP18 Prep Guard Cartridge listed here can withstand a maximum of 60 C.