SKU: 186006785
XSelect CSH C18 Method Validation Kit, 130Å, 2.5 µm, 2.1 mm X 150 mm, 3/pk

XSelect CSH C18 Method Validation Kit | 186006785


Streamline Purchasing with Customized Quotes

Streamline Purchasing with Customized Quotes

Shop on Waters.com and add items to your cart

Navigate to the Shopping Cart

Select Request a Quote to get your quote instantly


Product Description

This method validation kit consists of three XSelect CSH C18 columns packed with three different batches of sorbent. XSelect CSH C18 columns are general purpose C18 columns that provide alternative selectivity compared to other C18 sorbents. Charged Surface Hybrid (CSH) technology enables superior peak shape and increased loading capacity for basic compounds. Packed in ultra-low dispersion hardware, 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.

Specifications

  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    1 pH

  • pH Range Max

    11 pH

  • Maximum Pressure

    18000 psi (1240 Bar)

  • Endcapped

    Yes

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    2.5 µm

  • Endfitting Type

    Waters

  • Pore Size

    130 Å

  • Format

    Method Validation Kit

  • Surface Area

    185

  • System

    UHPLC, UPLC

  • Particle Technology

    CSH

  • USP Classification

    L1

  • Inner Diameter

    2.1 mm

  • Length

    150 mm

  • Carbon Load

    15 %

  • UNSPSC

    41115709

  • Brand

    XSelect

  • Product Type

    Column Kits

  • Units per Package

    3 pk

Product Support

Documents

Documents



What do you want to do?

What do you want to do?

Related Products

Back To Top Back To Top

XSelect CSH C18 Method Validation Kit, 130Å, 2.5 µm, 2.1 mm X 150 mm, 3/pk

Choose the XSelect CSH C18 Method Validation Kit to achieve the broadest range of selectivities in all applications while maintaining critical performance characteristics such as superior peak shape for basic compounds, low column bleed, ultra-efficiencies, and the ability to transition seamlessly between particle sizes and column formats. In addition, the analytical columns have high batch-to-batch consistency, allowing you to quickly build repeatable methods.

Invest in the XSelect CSH C18 Method Validation Kit, which includes three CSH-powered XSelect HPLC columns. This lab equipment provides the broadest range of selectivities and better performance in acidic, low-ionic-strength mobile phases that are LC/MS friendly. Each of the three columns in the XSelect Method Validation Kits is filled with a separate gel lot of stationary phase material. These chemistries are RP18, ODS, and Octadecyl.

XSelect CSH C18 columns are general-purpose C18 columns that provide alternative selectivity compared to other C18 sorbents. Charged Surface Hybrid (CSH) technology enables superior peak shape and increased loading capacity for basic compounds.

The XSelect CSH C18 Method Validation Kit includes lab equipment that allows you to execute better resolution separations, which are required for isolating and quantifying complex compounds. The XSelect CSH C18 Columns' distinct phases, which combine efficiency and selectivity to improve the resolution of exceedingly complex samples, make this possible. The lab equipment saves time and effort when constructing chromatographic tests by delivering higher separation performance, robustness, and throughput for HPLC assays while being fully compatible with all HPLC, UPLC, and UHPLC technologies.

You can achieve unequaled selectivity and reproducibility in your chromatographic analysis by utilizing the XSelect CSH C18 Method Validation Kit. The lab equipment has a wide range of analyte selectivity in order to separate closely eluting sample constituents.

Invest in the XSelect CSH C18 XP VanGuard Cartridge, 130Å, 2.5 µm, 2.1 mm X 5 mm, 3/pk as well. The cartridge is designed to prevent any harmful chemicals or particulate matter from entering the mobile phase.

What Is The pH Range For The XSelect CSH C18 Method Validation Kit?

The XSelect CSH C18 Method Validation Kit offers a broad working pH range of 1-11 pH.

What Maximum Pressure Can The XSelect CSH C18 Method Validation Kit Sustain?

The XSelect CSH C18 Method Validation Kit listed here offers a maximum pressure of 18000 psi (1240 Bar).