Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
12 pH |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
2.5 µm |
Endfitting Type |
Waters |
Pore Size |
130 Å |
Format |
Method Validation Kit |
Surface Area |
185 |
System |
UHPLC, UPLC |
Particle Technology |
BEH |
USP Classification |
L1 |
Inner Diameter |
4.6 mm |
Length |
150 mm |
Carbon Load |
18 % |
UNSPSC |
41115709 |
Brand |
XBridge |
Product Type |
Column Kits |
Units per Package |
3 pk |
XBridge BEH C18 Method Validation Kit, 130Å, 2.5 µm, 4.6 mm X 150 mm, 3/pk
This method validation kit consists of three Xbridge BEH C18 columns packed with three different batches of sorbent. As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH. The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.
Increase your lab throughput with the XBridge BEH C18 Method Validation Kit, which was created exclusively for that purpose. The lab equipment listed here consists of three columns with different C18 sorbents (RP-18, ODS, Octadecyl). The XBridge BEH C18 Method Validation Kit will suffice to satisfy your needs, whether you are developing a quality control method or a cutting-edge LC/MS test. The lab equipment improves pH stability, resulting in longer column lifetimes and lower lab costs due to fewer pieces of equipment needing to be replaced. You can also take advantage of assay ruggedness and improve column reliability using the analytical column. Furthermore, the XBridge BEH C18 Method Validation Kit provides exceptional peak shape and peak capacity by increasing particle efficiency.
As the XBridge packing utilizes proprietary procedures for bonding and end-capping, its ligand stability and chromatographic reproducibility at low pH enable it to show very little retention loss or peak shape degradation when compared to columns with conventional packing materials. This also means that the XBridge BEH C18 Method Validation Kit gives exceptional column lifetime without resorting to sterically hindering the stationary phase. The XBridge BEH C18 Method Validation Kit is highly durable under high pH conditions as well, as it combines the BEH particle synthesis process with advanced bonding and end-capping technologies, resulting in a highly coveted piece of lab equipment.
We recommend that you also use the XBridge BEH C18 XP VanGuard Cartridge, 130Å, 2.5 µm, 3.9 mm X 5 mm, 3/pk in conjunction with the analytical column to get the most accurate analytical results. The cartridge prevents the contamination of the mobile phase by filtering out any pollutants.
What Is The pH Range For The XBridge BEH C18 Method Validation Kit?
The XBridge BEH C18 Method Validation Kit listed here offers a wide operating pH of 1-12 pH.