Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
1 pH |
pH Range Max |
8 pH |
Maximum Pressure |
10000 psi (690 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
2.5 µm |
Endfitting Type |
Parker-style |
Pore Size |
100 Å |
Format |
Column |
Surface Area |
230 |
System |
UHPLC, UPLC |
Particle Technology |
HSS |
USP Classification |
L1 |
Inner Diameter |
4.6 mm |
Length |
150 mm |
Carbon Load |
15 % |
UNSPSC |
41115709 |
Brand |
XSelect |
Product Type |
Columns |
Units per Package |
1 pk |
XSelect HSS C18 XP Column, 100Å, 2.5 µm, 4.6 mm X 150 mm, 1/pk
Benefit from the XSelect HSS C18 XP Column in your lab as it has a general-purpose, high-performance C18 chemistry with exceptional retention and peak shape for all compounds. The 2.5 µm eXtended Performance [XP] lab equipment is packed in ultra-low dispersion hardware and enables exceptional separation performance, robustness, and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.
The XSelect HSS C18 XP Column is the perfect lab equipment for separating complicated combinations of basic and non-basic chemicals at low pH. The High Strength Silica (HSS) technology was created specifically for chromatography in order to provide benefits that include enhanced polar molecule retention and different selectivity. Furthermore, the HSS particle has the mechanical strength required to withstand UPLC pressures. This is why, as compared to other modern, high coverage, fully end-capped C18 columns, the XSelect HSS C18 XP Column provides alternate analyte selectivity. The lab equipment can also be used in UPLC separations and is fully scalable.
For complicated samples, better resolution separations are required to identify and quantify the sample constituents. The XSelect HSS C18 XP Column is able to combine efficiency and selectivity to help you improve the resolution of even the most complicated samples. In addition to this, the XSelect HSS C18 XP Column gives improved selectivity for acidic, alkaline, and neutral compounds, as well as improved retention for basic polar compounds when utilizing low-pH mobile phases.
Using extremely pure reagents, the reliable XSelect HSS C18 XP Column packing material is created in a cGMP, ISO 9001 certified plant. To ensure repeatable performance, each batch of XSelect HSS C18 XP Column material is tested, and the results are held to narrow specification ranges. Every column is also efficiency evaluated, and an eCord with a Certificate of Analysis and Performance Test Chromatogram is attached.
Waters recommends that you invest in the Select HSS C18 XP VanGuard Cartridge, 100Å, 2.5 µm, 3.9 mm X 5 mm, 3/pk, so that you can protect your column from harm and ensure its continued excellent performance.
What Pressure Can The XSelect HSS C18 XP Column Take?
The XSelect HSS C18 XP Column listed here is able to work well with operating pressures of up to 10000 psi (690 Bar).