Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
1 pH |
pH Range Max |
8 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
2.5 µm |
Endfitting Type |
Parker-style |
Pore Size |
100 Å |
Format |
Column |
Surface Area |
230 |
System |
UHPLC, UPLC |
Particle Technology |
HSS |
USP Classification |
L1 |
Inner Diameter |
2.1 mm |
Length |
150 mm |
Carbon Load |
15 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
XSelect |
Product Type |
Columns |
Units per Package |
1 pk |
XSelect HSS C18 Column, 100Å, 2.5 µm, 2.1 mm X 150 mm, 1/pk
Choose the all-purpose C18 bonded phase XSelect HSS C18 Column to obtain superior peak shape for basic chemicals, enhanced retention (vs. XBridge C18 columns), and outstanding column lifetimes at low pH. XSelect HSS C18 is a general purpose, high-performance C18 chemistry with exceptional retention and peak shape for all compounds. The selectivity and retention when using this lab equipment is similar to that of the majority of contemporary, completely end-capped, high-coverage C18 columns made of silicon. The XSelect HSS C18 Column also demonstrates minimum column bleed, great batch-to-batch consistency, ultra-efficiencies, and seamless column format conversion. As a result, you can benefit from the XSelect HSS C18 Column's adaptability in meeting all of your analytical demands.
For complicated samples, higher resolution separations are necessary in order to identify and quantify the sample's contents. By utilizing the combined efficiency and selectivity of the XSelect HSS C18 Column, you may improve the resolution of extremely complex samples. Furthermore, the XSelect HSS C18 Column can be trusted to give improved selectivity for acidic, alkaline, and neutral compounds, as well as improved retention for basic polar compounds when utilizing low-pH mobile phases.
The complex combinations of basic and non-basic chemicals found in separations with low pH are ideally suited for the XSelect HSS C18 Column. The High Strength Silica (HSS) technology found in lab equipment was created specifically to provide benefits to chromatography, such as improved polar component retention and various selectivity. The HSS particle also provides the required mechanical strength for enduring UPLC pressures. Because of this, you receive alternate analyte selectivity when comparing the XSelect HSS C18 Column to the most recent, high coverage, fully end-capped C18 columns. Additionally, it is completely transferrable to UPLC separations and scalable.
We recommend that you also invest in the XSelect HSS C18 XP VanGuard Cartridge, 100Å, 2.5 µm, 2.1 mm X 5 mm, 3/pk. The cartridge is a standalone piece that fastens to the column and keeps chemicals and particulates out of the mobile stream.
Across What pH Range Does The XSelect HSS C18 Column Operate?
The XSelect HSS C18 Column listed here is able to function well across the 1-8 pH range.
What Is The Maximum Pressure That The XSelect HSS C18 Column Can Sustain?
This particular XSelect HSS C18 Column is able to take a maximum of 18000 psi (1240 Bar) pressure.