SKU: 186006736
XSelect HSS C18 Column, 100Å, 2.5 µm, 2.1 mm X 150 mm, 1/pk

XSelect HSS C18 Column | 186006736


Streamline Purchasing with Customized Quotes

Streamline Purchasing with Customized Quotes

Shop on Waters.com and add items to your cart

Navigate to the Shopping Cart

Select Request a Quote to get your quote instantly


Product Description

XSelect HSS C18 is a general purpose, high performance C18 chemistry with exceptional retention and peak shape for all compounds. Packed in ultra-low dispersion hardware, 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.

Specifications

  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Silica

  • pH Range Min

    1 pH

  • pH Range Max

    8 pH

  • Maximum Pressure

    18000 psi (1240 Bar)

  • Endcapped

    Yes

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    2.5 µm

  • Endfitting Type

    Parker-style

  • Pore Size

    100 Å

  • Format

    Column

  • Surface Area

    230

  • System

    UHPLC, UPLC

  • Particle Technology

    HSS

  • USP Classification

    L1

  • Inner Diameter

    2.1 mm

  • Length

    150 mm

  • Carbon Load

    15 %

  • eCord

    Yes

  • UNSPSC

    41115709

  • Brand

    XSelect

  • Product Type

    Columns

  • Units per Package

    1 pk

Product Support

Documents

Documents



What do you want to do?

What do you want to do?

Related Products

Back To Top Back To Top

XSelect HSS C18 Column, 100Å, 2.5 µm, 2.1 mm X 150 mm, 1/pk

Choose the all-purpose C18 bonded phase XSelect HSS C18 Column to obtain superior peak shape for basic chemicals, enhanced retention (vs. XBridge C18 columns), and outstanding column lifetimes at low pH. XSelect HSS C18 is a general purpose, high-performance C18 chemistry with exceptional retention and peak shape for all compounds. The selectivity and retention when using this lab equipment is similar to that of the majority of contemporary, completely end-capped, high-coverage C18 columns made of silicon. The XSelect HSS C18 Column also demonstrates minimum column bleed, great batch-to-batch consistency, ultra-efficiencies, and seamless column format conversion. As a result, you can benefit from the XSelect HSS C18 Column's adaptability in meeting all of your analytical demands.

For complicated samples, higher resolution separations are necessary in order to identify and quantify the sample's contents. By utilizing the combined efficiency and selectivity of the XSelect HSS C18 Column, you may improve the resolution of extremely complex samples. Furthermore, the XSelect HSS C18 Column can be trusted to give improved selectivity for acidic, alkaline, and neutral compounds, as well as improved retention for basic polar compounds when utilizing low-pH mobile phases.

The complex combinations of basic and non-basic chemicals found in separations with low pH are ideally suited for the XSelect HSS C18 Column. The High Strength Silica (HSS) technology found in lab equipment was created specifically to provide benefits to chromatography, such as improved polar component retention and various selectivity. The HSS particle also provides the required mechanical strength for enduring UPLC pressures. Because of this, you receive alternate analyte selectivity when comparing the XSelect HSS C18 Column to the most recent, high coverage, fully end-capped C18 columns. Additionally, it is completely transferrable to UPLC separations and scalable.

We recommend that you also invest in the XSelect HSS C18 XP VanGuard Cartridge, 100Å, 2.5 µm, 2.1 mm X 5 mm, 3/pk. The cartridge is a standalone piece that fastens to the column and keeps chemicals and particulates out of the mobile stream.

Across What pH Range Does The XSelect HSS C18 Column Operate?

The XSelect HSS C18 Column listed here is able to function well across the 1-8 pH range.

What Is The Maximum Pressure That The XSelect HSS C18 Column Can Sustain?

This particular XSelect HSS C18 Column is able to take a maximum of 18000 psi (1240 Bar) pressure.