Chemistry |
PFP/Fluoro-Phenyl |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
8 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
No |
Bonding Technology |
Fluoro-Phenyl |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
2.5 µm |
Endfitting Type |
Parker-style |
Pore Size |
130 Å |
Format |
Column |
Surface Area |
185 |
System |
UHPLC, UPLC |
Particle Technology |
CSH |
USP Classification |
L43 |
Inner Diameter |
2.1 mm |
Length |
150 mm |
Carbon Load |
10 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
XSelect |
Product Type |
Columns |
Units per Package |
1 pk |
XSelect CSH Fluoro-Phenyl Column, 130Å, 2.5 µm, 2.1 mm X 150 mm, 1/pk
The XSelect CSH Fluoro-Phenyl column is designed to optimize selectivity differences, allowing you the most method development freedom possible, particularly when using low pH mobile phases. The non-end-capped sorbent promotes acidic chemical retention. 2.5 µm eXtended Performance [XP] columns with ultra-low dispersion technology provide excellent separation performance, robustness, and throughput for HPLC investigations while paving the way for UPLC adoption.
By selecting our instruments, software, chemistries, and services, you will have all of the tools you need to succeed in any analysis. Waters Quality Parts are the only ones that have been tested and verified for constant optimal performance of your Waters systems, so they function best with your Waters instruments. You can be confident of constant instrument operation, accurate and reproducible results, and sustained system compliance when you use Waters Quality Parts.
Waters XSelect CSH Fluoro-Phenyl Columns consistently provide excellent quality and the appropriate results for liquid chromatography. These columns, like all Waters equipment, are built in dedicated, state-of-the-art Waters facilities. All Water manufacturing plants and facilities adhere to the most stringent cGMP and ISO 9001 standards. Each stage of the manufacturing process is meticulously checked and managed, ensuring that the equipment in your labs is of the greatest quality.
With the right lab equipment, you can boost your productivity. Check out our shop for lab equipment to discover more about variations of the same product, such as the XSelect CSH Fluoro-Phenyl Column, or to locate more goods that work with it; you may browse around our website, refer to our catalog, and ensure your lab needs are addressed as needed.
You may also be interested in reviewing the XSelect CSH Phenyl XP VanGuard Cartridge, 130Å, 2.5 µm, 2.1 mm X 5 mm, 3/pk; XSelect CSH Fluoro-Phenyl VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. XSelect CSH Fluoro-Phenyl analytical columns containing 2.5 µm sorbent particles.
How Do I Go About Filtration?
Before adding the sample, draw approximately 1 mL of air into the syringe. This will enable the air to escape along with the sample when dispensing from the syringe. This "air purge" helps minimize fluid retention within the filter mechanism. Proceed to fill the syringe with the filtered solution. Holding the filter device in one hand, gently twist the filled syringe onto the filter device, ensuring not to exert excessive force. Apply gentle pressure to initiate the filtration process.