Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Temperature Limits |
45 C |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Bonding Technology |
T3 |
Silanol Activity |
Medium |
Particle Shape |
Spherical |
Particle Size |
3.5 µm |
Endfitting Type |
Waters |
Pore Size |
100 Å |
Format |
Method Validation Kit |
Surface Area |
230 |
System |
HPLC |
Particle Technology |
HSS |
USP Classification |
L1 |
Inner Diameter |
4.6 mm |
Length |
100 mm |
Carbon Load |
11 % |
UNSPSC |
41115709 |
Brand |
XSelect |
Product Type |
Column Kits |
Units per Package |
3 pk |
XSelect HSS T3 Method Validation Kit, 100Å, 3.5 µm, 4.6 mm X 100 mm, 3/pk
Use the Waters XSelect HSS T3 Method Validation Kit to improve selectivity for acidic, alkaline, and neutral chemicals. When constructing a chromatographic experiment, the column delivers a successful combination of efficiency and selectivity to improve the resolution of very complex samples, saving you important time and work. When compared to BEH and CSH particles, the enhanced silanophilicity of the HSS particle offers benefits, including improved polar compound retention and noticeably different selectivity. Additionally, the XSelect HSS T3 Method Validation Kit offers exceptional repeatability and transferability.
All Waters lab equipment is created in a cGMP, ISO 9001 certified facility utilizing ultra-pure chemicals and is manufactured to the highest industrial standards. Additionally, every column is manually examined to guarantee that you only get high-quality goods that produce accurate results that can be repeated.
To complete the range of lab equipment, browse our catalog for more items that are similar to those listed here as well as for items that are compatible with them. Along with providing information on where to find our offices and how to get in touch with our personnel anywhere in the world, the catalog also lets you shop for lab equipment.
With the Waters XSelect HSS T3 Method Validation Kit, you can retain polar molecules longer than with the conventional C18 phase. When utilizing up to 100% aqueous mobile phases, the reversed-phase analytical column performs better. The XSelect HSS T3 Method Validation Kit has the widest retention capabilities for combinations of polar and non-polar chemicals when employing conventional reversed-phase mobile phases.
Use the XSelect HSS T3 VanGuard Cartridge, 100Å, 3.5 µm, 3.9 mm X 5 mm, 3/pk in conjunction with your analytical column in order to eliminate the unwanted chemical or particulate contaminants from the mobile stream. The use of the cartridge will ensure more accurate and reliable results while increasing the lifetime of the column.
What Is The pH Range For The Waters XSelect HSS T3 Method Validation Kit?
The XSelect HSS T3 Method Validation Kit listed here is able to work well within the 2-8 pH range.
What Is The Maximum Pressure Recommended For The Waters XSelect HSS T3 Method Validation Kit?
The XSelect HSS T3 Method Validation Kit has a recommended maximum pressure of 6000 psi (415 Bar).