Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
2 pH |
pH Range Max |
11 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Bonding Technology |
Shield RP18 |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
2.5 µm |
Endfitting Type |
Waters |
Pore Size |
130 Å |
Format |
Method Validation Kit |
Surface Area |
185 |
System |
UPLC, UHPLC |
Particle Technology |
BEH |
USP Classification |
L1 |
Inner Diameter |
3 mm |
Length |
100 mm |
Carbon Load |
17 % |
UNSPSC |
41115709 |
Brand |
XBridge |
Product Type |
Column Kits |
Units per Package |
3 pk |
XBridge BEH Shield RP18 Method Validation Kit, 130Å, 2.5 µm, 3 mm X 100 mm, 3/pk
To ensure a successful separation, optimize the test circumstances using the XBridge BEH Shield RP18 Method Validation Kit. The XBridge columns offer an alternative selectivity and can function effectively in a wide pH range with a number of solvents.
The XBridge BEH Shield RP18 Method Validation Kit is an essential and effective instrument for HPLC method development and is a complement to the XBridge BEH C18 and C8 phases. When compared to straight-chain alkyl columns, the lab apparatus's integrated carbamate group in the bonded phase ligand offers alternate selectivity, particularly for phenolic chemicals.
The XBridge BEH Shield RP18 Method Validation Kit can be used to produce greater base separation. The XBridge BEH Shield RP18 Method Validation Kit, which relies on the patented Shield Technology and produces extremely symmetrical and effective peaks, shows reduced silanol interactions with basic analytes. The "Shielding" effect, which leads to enhanced peak shape, is caused by the deactivation of fundamental analytes that occurs in the laboratory apparatus. This is a great improvement over the common C18 columns that are sold commercially, which have weak cation exchange with residual surface silanols and poor peak symmetry due to secondary interactions with basic chemicals.
You can create robust separations faster and with more assurance with the XBridge BEH Shield RP18 Method Validation Kit to fully harness the power of pH.
Visit our online store to view the full selection of Waters Xbridge BEH Shield Columns, which come in a range of particle and pore diameters. You can buy lab equipment from the store as well.
You may also want to use the XBridge BEH Shield RP18 XP VanGuard Cartridge, 130Å, 2.5 µm, 2.1 mm X 5 mm, 3/pk. Manufactured using the exact packing materials that are present in the column, the cartridge is designed especially to prevent any chemical or particulate matter from entering mobile phase and interfering with the analysis.
What Is The XBridge BEH Shield RP18 Method Validation Kit Offered By The XBridge BEH Shield RP18 Method Validation Kit?
The Waters XBridge BEH Shield RP18 Method Validation Kit mentioned here utilizes the 2-11 pH range.
Is There A Maximum Pressure That The XBridge BEH Shield RP18 Method Validation Kit Can Tolerate?
The XBridge BEH Shield RP18 Method Validation Kit is able to tolerate a maximum of 18,000 psi (1240 Bar) pressure.