Chemistry |
Cyano (CN) |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Maximum Pressure |
10000 psi (690 Bar) |
Endcapped |
No |
Silanol Activity |
High |
Particle Shape |
Spherical |
Particle Size |
2.5 µm |
Endfitting Type |
Parker-style |
Pore Size |
100 Å |
Format |
Column |
Surface Area |
230 |
System |
UHPLC, UPLC |
Particle Technology |
HSS |
USP Classification |
L10 |
Inner Diameter |
4.6 mm |
Length |
100 mm |
Carbon Load |
5 % |
UNSPSC |
41115709 |
Brand |
XSelect |
Product Type |
Columns |
Units per Package |
1 pk |
XSelect HSS Cyano (CN) Column, 100Å, 2.5 µm, 4.6 mm X 100 mm, 1/pk
Add the XSelect HSS Cyano (CN) Column to your lab because it features an ultra-high-performance general-purpose propyl cyano bonded phase that provides chromatographic analysis with a number of important advantages. The column may readily produce a superior peak shape for bases, aid in retention, and provide extraordinarily extended column lives at low pH. Because of these factors, it is a dependable and essential piece of laboratory equipment. Both reversed-phase and normal-phase chromatography are possible with this column. The XSelect HSS CN HPLC columns from XSelect are fully scalable and convertible to ACQUITY UPLC separations.
Because the XSelect HSS Cyano (CN) Column uses the HSS (High Strength Silica) technology developed by Waters to complement the chromatographic performance of BEH (Ethylene Bridged Hybrid) and CSH (Charged Surface Hybrid) particles, you can achieve the best separation in the laboratory and overcome chromatography challenges. Higher silanophilicity in the HSS technology leads to greater polar molecule retention and dramatically different selectivity. The HSS technology was created to provide the mechanical strength required for working with UPLC pressures.
When lesser chromatographic retention is required for strongly retained substances, the XSelect HSS Cyano (CN) Column is ideal. The increase in organic content is used to reduce compound retention durations when employing C18 phases. In this case, however, a Cyano Column is far more cost-effective because its moderate retention properties allow you to use less organic solvent in the mobile phase, resulting in faster chromatographic analysis. 2.5 µm eXtended Performance [XP] columns, packed in ultra-low dispersion hardware, provide superior separation performance, resilience, and throughput for HPLC tests while allowing for a smooth transition to UPLC adoption.
Waters is dedicated to developing and delivering superior analytical tools to fulfill your chromatographic requirements. Visit our website to shop for lab equipment and contact us with any questions you may have. You may also be interested in XSelect HSS Cyano (CN) XP VanGuard Cartridge, 100Å, 2.5 µm, 3.9 mm X 5 mm, 3/pk; XSelect HSS CN VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 4.6 mm I.D. XSelect HSS CN analytical columns containing 2.5 µm sorbent particles.
What Are The Operating Limitations for XSelect HSS Cyano (CN) Column?
The XSelect HSS Cyano (CN) Column can be operated at a maximum pressure of 10,000 psi (or 690 Bar) and a pH range of 2 to 8.