Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
11 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
2.5 µm |
Endfitting Type |
Parker-style |
Pore Size |
130 Å |
Format |
Column |
Surface Area |
185 |
System |
UHPLC, UPLC |
Particle Technology |
CSH |
USP Classification |
L1 |
Inner Diameter |
3 mm |
Length |
75 mm |
Carbon Load |
15 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
XSelect |
Product Type |
Columns |
Units per Package |
1 pk |
XSelect CSH C18 Column, 130Å, 2.5 µm, 3 mm X 75 mm, 1/pk
Perform better resolution separations, which are necessary for complex samples in order to isolate and quantify the materials, with the XSelect CSH C18 Column. This is made possible by the special phases of the analytical column in the XSelect CSH C18 Column, which combine efficiency and selectivity to improve the resolution of extremely complex samples. The lab equipment will save you time and effort while being fully compatible with all HPLC, UPLC, and UHPLC technologies while you are constructing a chromatographic test. Additionally, because the analytical column provides good batch-to-batch consistency, it enables you to swiftly create robust procedures.
Deliver unsurpassed selectivity and repeatability for your chromatographic analysis using the XSelect CSH C18 Column. The lab equipment is made to provide a range of analyte selectivity to separate components of closely eluting samples. In contrast to other commercially available C18 sorbents, the column can be utilized as a general-purpose column and offers an alternative selectivity. You may address column-related issues such as peak shape asymmetry and poor loading for basic chemicals, column bleed, and sluggish mobile-phase re-equilibration with the use of the Charged Surface Hybrid (CSH) technology included in the column.
Comparing the XSelect CSH C18 Column to core-shell columns reveals that it offers superior performance and comparable backpressure. Due to the utilization of Charged Surface Hybrid (CSH) technology in the analytical column, the XSelect CSH C18 Column also provides better loading capacity and particle size scalability, like other fully-porous particle columns. The performance of liquid chromatography in acidic, low ionic strength mobile phases is considerably enhanced by CSH Technology, the next step in particle technology. Maximum method development flexibility is also provided by the column, particularly when using mobile phases with low pH. This is due to the XSelect CSH C18 Column's non-end-capped sorbent's increased retention of acidic chemicals. The XSelect CSH C18 Column is an essential piece of lab equipment since it also has ultra-low dispersion hardware, enabling superb separation performance and a smooth transition path toward UPLC adoption.
Protect your XSelect column from harm using the XSelect CSH C18 XP VanGuard Cartridge, 130Å, 2.5 µm, 2.1 mm X 5 mm, 3/pk.
What Is The pH Range For The XSelect CSH C18 Column?
This particular XSelect CSH C18 Column is able to support a pH range of 1-11 pH.
What Maximum Pressure Does The XSelect CSH C18 Column Support?
The XSelect CSH C18 Column listed here is able to sustain a maximum pressure of up to 18000 psi (1240 Bar).