Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
2 pH |
pH Range Max |
11 pH |
Maximum Pressure |
10000 psi (690 Bar) |
Endcapped |
Yes |
Bonding Technology |
Shield RP18 |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
2.5 µm |
Endfitting Type |
Parker-style |
Pore Size |
130 Å |
Format |
Column |
Surface Area |
185 |
System |
UHPLC, UPLC |
Particle Technology |
BEH |
USP Classification |
L1 |
Inner Diameter |
4.6 mm |
Length |
50 mm |
Carbon Load |
17 % |
UNSPSC |
41115709 |
Brand |
XBridge |
Product Type |
Columns |
Units per Package |
1 pk |
XBridge BEH Shield RP18 Column, 130Å, 2.5 µm, 4.6 mm X 50 mm, 1/pk
Enhance the essential test conditions required for a successful separation using the XBridge BEH Shield RP18 Column. With this lab equipment, you may successfully operate over a wide pH range with a variety of solvents since the XBridge BEH Shield RP18 Column gives an alternate selectivity.
The XBridge BEH Shield RP18 Columns make it simple to conduct superior base separation. There is a decrease in silanol interactions with basic analytes when using the XBridge BEH Shield RP18 Column. The lab equipment uses the proprietary Shield Technology to produce extremely symmetrical, efficient peaks with better peak shape. This is made possible by the "Shielding" effect, which is the deactivation of basic analytes. The XBridge BEH Shield RP18 Column performs better than conventional C18 columns, which have poor peak symmetry because of secondary interactions with basic chemicals caused by weak cation exchange with lingering surface silanols.
The analytical column is the standard for LC method toughness and lifespan because it offers greater pH stability over the widest pH range, along with excellent efficiency and symmetrical peak form. Utilize pH's strength and the lab equipment's adaptability with confidence to create solid separations. The XBridge BEH Shield RP18 Column is a good fit for your demands whether you need reliable HPLC procedures, seamless UPLC transferability, or preparative scaling for product separation.
When you buy from Waters, you can be sure that you will get only the best lab equipment to satisfy your analytical needs. This is because we maintain unequaled product repeatability by meticulously monitoring and tightly controlling every stage of our manufacturing process. From raw material characterization through final batch analysis, testing is a part of this process. You have the assurance that the XBridge BEH Shield RP18 Column will give the same performance year after year thanks to this strict respect to standards.
Protect your column from harm using the XBridge BEH Shield RP18 XP VanGuard Cartridge, 130Å, 2.5 µm, 3.9 mm X 5 mm, 3/pk.
Across What pH Range Does The XBridge BEH Shield RP18 Column Operate?
The Waters XBridge BEH Shield RP18 Column listed here is able to work well within the 2-11 pH range.
What Is The Maximum Pressure Recommended For The XBridge BEH Shield RP18 Column?
For the XBridge BEH Shield RP18 Column, the recommended maximum pressure is 10,000 psi (690 Bar).