Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
2 pH |
pH Range Max |
11 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Bonding Technology |
Shield RP18 |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
2.5 µm |
Endfitting Type |
Parker-style |
Pore Size |
130 Å |
Format |
Column |
Surface Area |
185 |
System |
UPLC, UHPLC |
Particle Technology |
BEH |
USP Classification |
L1 |
Inner Diameter |
3 mm |
Length |
75 mm |
Carbon Load |
17 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
XBridge |
Product Type |
Columns |
Units per Package |
1 pk |
XBridge BEH Shield RP18 Column, 130Å, 2.5 µm, 3 mm X 75 mm, 1/pk
Use the full potential of pH to create reliable separations in less time and with greater assurance using the XBridge BEH Shield RP18 Column. For the durability and lifespan of the liquid chromatography process, lab equipment is a standard in the industry. With the analytical column, you receive high efficiency, symmetrical peak form, and superior pH stability over the widest pH range.
Count on the XBridge BEH Shield RP18 Column to consistently deliver unsurpassed peak shape and peak capacity while maximizing particle efficiency. The XBridge BEH Shield RP18 Column is intended to increase productivity. This is accomplished by extending the column lifetime through better pH stability. The XBridge BEH Shield RP18 Column's improved reliability also contributes to the assay's robustness.
Unlike any other column, the XBridge BEH Shield RP18 Column overcomes difficult chromatographic problems. Due to its adaptability, it is a vital asset to any lab as it can accommodate a wide range of requirements. The XBridge BEH Shield RP18 Column may be depended upon for preparative scaling for product isolation, seamless UPLC transferability, or robust HPLC techniques.
Superior base separation is possible with the XBridge BEH Shield RP18 Column. The XBridge BEH Shield RP18 Column, which employs the patented Shield Technology and produces extremely symmetrical and effective peaks, shows reduced silanol interactions with basic analytes. The "Shielding" effect, which arises from the deactivation of fundamental analytes, improves peak shape.
According to extensive research conducted by Waters, reproducible column performance is one of the most important variables for technique dependability. In order to guarantee unsurpassed lab equipment repeatability, every step of our column manufacturing process is meticulously monitored and rigorously controlled. Testing from raw material characterization through final batch analysis is part of this investigation. By following this procedure, we ensure that the XBridge BEH Shield RP18 Column will perform consistently from year to year.
We recommend that you also use the XBridge BEH Shield RP18 XP VanGuard Cartridge, 130Å, 2.5 µm, 2.1 mm X 5 mm, 3/pk in conjunction with the column to ensure the lab equipment lasts a long time. It is manufactured using the same packing materials as the column, making them ideally suited to work together. It works by preventing the entrance of any unwanted chemical or particulate matter in the mobile stream, thus improving the efficiency and accuracy of the analysis.
What pH Range Does The XBridge BEH Shield RP18 Column Offer?
The XBridge BEH Shield RP18 Column listed here is able to work well within the 2-11 pH range.
Is There A Maximum Pressure Limit Recommended For The XBridge BEH Shield RP18 Column?
For this XBridge BEH Shield RP18 Column, the maximum recommended pressure is 18,000 psi (415 Bar).